Wheel diameter measuring gauge, IDK-BT
IDK-BT [Revision 2.2] 4
th
September 2017
15
Buttons:
- diameter measurement
- averaging reset
to continue the measurement with averaging:
press
Green
button;
display shows the value of pressing counter “
n x
”, where
x
– quantity of av-
eraged values;
in a 1 second display shows an average value over the set of metering (over
the quantity of
Green
button pressings)
move the gauge to a new position and repeat the measuring. (The total quan-
tity of measurements averaged in this way can run up to 9999.)
Press
Red
button to reset averaging result at switching to another wheel.
12.4. Measurements with database maintenance
A fully functional work with the gauge involves maintenance of the measure-
ments database.
To take measurements:
select in the main menu
Profilometer > Measurement
, the window of pa-
rameters input will appear
If necessary, fill in/edit the required fields
to save parameters, press the
Save
button, and the program will offer the se-
lected measurement scheme (see par.
13.5.
):