60
Press ESC key and return to FUNCTION PAGE.
Chapter 5 Configuring & Programming software
Users who are familiar with the logic boxes of Boolean algebra can use the xLogicsoft. In fact xLogicsoft
adapts the function block programming way. xLogicsoft is available as a programming package for the
PC. This mode provides many features, for example:
A graphic interface for offline creation of your circuit program by means of
Function Block Diagram (function chart)
Simulation of your circuit program on the PC
Generating and printing of an overview chart for the circuit program
Saving a backup of the circuit program on the hard drive or other media
Rievtech configuration of blocks
Transferring the circuit program
–
from the xLogic to the PC and
–
from the PC to xLogic
Online test: Display of status changes and process variables of xLogic in RUN mode:
–
Status of a digital I/O, shift register bits and cursor keys
–
The values of all analog I/Os
–
The results of all blocks
–
The current values (including the times) of selected blocks
–
Change the output(the input pin of the output cannot be connected) status
via xLogicsoft
Starting and stopping circuit program execution via the PC (RUN, STOP).
The xLogic alternative
As you can see, xLogicsoft represents an alternative to conventional engineering
methods:
1.
You start by developing the circuit program on your desktop.
2.
You simulate the circuit program on your computer and verify its functions, before
you actually implement it in your system.
3.
You can add comments to the circuit program and create hard-copies.
4.
You save a copy of your circuit program to the file system on your PC, to make it
directly available for any modifications.
5.
It takes only a few key actions to download the circuit program to xLogic.
6.
Under Simulate mode in xLogicsoft, you can study how to program via the panel
Содержание ELC-12AC-R-N
Страница 1: ...Applied to ELC PR series Ver 3 0 Programmable Relay User s Manual Rievtech Electronic Co Ltd...
Страница 27: ...27 PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension PR 24 series...
Страница 31: ...31 AC type digital inputs Analog Inputs DC 0 10V Analog inputs current Inputs 0 20mA...
Страница 40: ...40...
Страница 120: ...120 C Analog input value of CPU and extensions D Analog output value of CPU and extensions...
Страница 121: ...121 E F digital flag status F AF analog flag value...
Страница 122: ...122 G M status H AM value...
Страница 221: ...221 7 Click Install button to install Program is being installed...
Страница 247: ...247 Right click Q2 and then click Set Output State Click OK button and the Q2 of xLogic will be turned off...
Страница 250: ...250...
Страница 256: ...256 You can read the parameters from the PLC...
Страница 258: ...258...
Страница 264: ...264 Our xLogicApp Smart phone is tcp client Interface configure Modbus Poll works as TCP client...
Страница 267: ...267 TCP Sever 192 168 0 227 port 8004 is ok TCP Sever 192 168 0 227 port 8005 is ok...
Страница 268: ...268 TCP Sever 192 168 0 227 port 8006 is ok TCP Sever 192 168 0 227 port 8007 is ok...
Страница 269: ...269 TCP Sever 192 168 0 227 port 8008 is ok TCP Sever 192 168 0 227 port 8009 is ok...
Страница 290: ...290 Slave1 IP 192 168 0 101 TCP server port 8001 Slave2 IP 192 168 0 102 TCP server port 8002...
Страница 291: ...291 Slave3 IP 192 168 0 103 TCP server port 8003 Step 2 Program in master and slave Master program...
Страница 292: ...292 B001 is used to write I1 status to F1 of slave1 the Remote 1 is the target1 in the network parameter settings...
Страница 293: ...293 B002 is used to write I1 status to F1 of slave1 the Remote 2 is the target2 in the network parameter settings...
Страница 305: ...305 Slave3 IP 192 168 0 103 UDP Server port 8003 Step 2 Program in master and slave Master program...
Страница 317: ...317 Network settings You can view the network parameters in such table...
Страница 328: ...328 Program in master You need use the MODBUS BLOCK to realize the data transmission between master and slaves...
Страница 329: ...329 B001 Transfer the I1 IA status from the master to the Q1 QA of the slave1 Setting as follows...
Страница 330: ...330 B002 Transfer the I1 IA status from the master to the Q1 QA of the slave2 Setting as follows...
Страница 331: ...331 B005 Read the I1 IA status from the slave1 to the F11 F20 of the master Setting as follows...
Страница 332: ...332 B006 Read the I1 IA status from the slave2 to the F21 F30 of the master Setting as follows...
Страница 346: ...346 7 4 2 The scheme of xLogic The circuit diagram of industry gate...
Страница 350: ...350 Components S1 S4 make contact Momentary switch B1 make contact Daylight control switch Circuit diagram by xLogicsoft...
Страница 353: ...353 7 6 2 The scheme of xLogic Components K1 main contactor...
Страница 357: ...357 4 cursors Cursor key Type 1x MODBUS code 02 C1 C4 256 259 BIT R...
Страница 392: ...392...