background image

 

 

I

NTRODUCTION

 

 
Congratulations on purchasing a 

UPS Vision 

product and welcome to 

Riello UPS

! To use the support service offered by 

Riello UPS

, visit the site 

www.riello-ups.com

 

 
 
Our Company is a specialist in the design, development and manufacturing of uninterruptible power supplies (UPS).  
 
The UPS described in this manual is a high quality product which has been carefully designed and built in order to 
guarantee the highest levels of performance.  
 
 
This device can be installed by anyone on the condition that they have 

READ THIS INSTALLTION AND USER 

MANUAL CAREFULLY. 
 
The UPS and the Battery Box generate DANGEROUS internal electrical voltages. All maintenance operations 
must be carried out by suitably qualified operators. 
 
 

This manual contains detailed instructions for using and installing the UPS and any additional Battery boxes. 

For information on how to use and maximise the performance of your device, please retain the CD containing 
this manual and read it carefully before operating the equipment.   
 
 
 

E

NVIRONMENTAL 

P

ROTECTION

 

 
In the development of its products, the company devotes abundant resources to analysing the environmental aspects. 
All our products pursue the objectives defined in the environmental management system developed by the company in 
compliance with applicable standards. 
 
 
No hazardous materials such as CFCs, HCFCs or asbestos are used in this product. 
 
 
When evaluating packaging, the choice of material has been made favouring recyclable materials. 
For correct disposal, please separate and identify the type of material of which the packaging is made according to the 
table below. Dispose of all material in compliance with applicable standards in the country in which the product is used. 
 
 
 

D

ESCRIPTION

 

M

ATERIAL

 

Box Cardboard 

Packaging corner  

Stratocell 

Protective bag  

Polythene 

Accessories bag 

Polythene 

 
 
 

D

ISPOSING OF THE PRODUCT

 

 
The UPS and the Battery Box contain electronic PCBs and batteries which are considered TOXIC and HAZARDOUS 
waste. When the product reaches the end of its operating life, dispose of it in accordance with applicable local legislation. 
Disposing of the product correctly contributes to respecting the environment and personal health. 
 
 
 

 

© 

The reproduction of any part of this manual, in whole or in part, is forbidden without the prior consent of the manufacturer. 
In order to make improvements, the manufacturer reserves the right to modify the product described at any moment and without 
notice. 

Содержание VST 1100

Страница 1: ......

Страница 2: ...the environmental aspects All our products pursue the objectives defined in the environmental management system developed by the company in compliance with applicable standards No hazardous materials...

Страница 3: ...OM THE BATTERY 9 SWITCHING OFF THE UPS 9 DISPLAY PANEL MESSAGES 10 UPS STATUS MESSAGES 10 MEASUREMENT DISPLAY AREA 11 CONFIGURING THE OPERATING MODE 12 POSSIBLE SETTINGS 12 ADDITIONAL FUNCTIONS 12 SOF...

Страница 4: ...system available for network devices servers and conventional storage systems The VISION series is a range of UPS which utilises the very latest Line Interactive technology and sinusoidal output volt...

Страница 5: ...5 UPS VIEWS FRONT VIEW Display Removable front panel Multipurpose buttons Battery pack connector ON OFF Switch Battery pack retention panel...

Страница 6: ...EAR VIEW 800VA 1100VA Model 1500VA 2000VA Model Communication port RS232 Cooling fans USB communication port IEC 10A output socket Circuit breaker Energyshare Communication Card Slots IEC 10A input pl...

Страница 7: ...ect Load level indicator ON button Configuration area STAND BY button Maintenance request Regular operation Timer Mains operation Measurement display area Battery operation Stand by alarm AVR active E...

Страница 8: ...m bad weather The relative humidity in the environment must not exceed the maximum values shown in the Technical Data table The ambient temperature whilst the UPS is in operation must remain between 0...

Страница 9: ...s which can be downloaded from the web site www riello ups com SWITCHING ON FROM THE MAINS 1 Press the ON button for 1 second After pressing it all the icons on the display light up for 1 second and t...

Страница 10: ...tage charge of the batteries Dynamic Indicates the percentage of charge applied to the UPS compared with the nominal value Flashing Maintenance is required Contact the support centre Fixed Indicates t...

Страница 11: ...examples are shown below GRAPHIC EXAMPLE 1 DESCRIPTION GRAPHIC EXAMPLE 1 DESCRIPTION Mains voltage Battery charge percentage Mains frequency Total battery voltage UPS output voltage Applied load perce...

Страница 12: ...switched on the load is disconnected in the event of a mains blackout If the input mains deviates from the established tolerances the UPS automatically switches to Stdby mode and disconnects the load...

Страница 13: ...full display of the status of the UPS via USB or RS232 For a list of possible configurations available to the user refer to the UPS Configuration paragraph INSTALLATION OPERATIONS 1 Connect one of the...

Страница 14: ...attery discharge 1 65000 sec in 1 sec steps Battery low warning Estimated autonomy time remaining for the battery low warning 3 min 1 255 min in 1 min steps Battery test Interval of time for the autom...

Страница 15: ...UPS refer to the manual provided 2 TXD 3 RXD 4 Programmable input default disabled 5 GND 6 Power supply DC Imax 20mA 7 Programmable input default disabled 8 Programmable output default low battery pr...

Страница 16: ...INS FAILURE THE BATTERY PACK IS VERY HEAVY USE EXTREME CAUTION WHEN REPLACING IT 1 Set the UPS in battery swap mode by pressing and holding both the ON and SEL button for 4 seconds See par USE Operati...

Страница 17: ...in the same number and type of batteries see the label located on the battery pack near the connector 5 Insert the new battery pack into the compartment sliding it into the UPS Replace the battery pac...

Страница 18: ...IS NOT POWERED THE UPS IS IN STAND BY MODE Press the ON button on the front panel to power the loads NO CONNECTION TO THE LOAD Check the connection to the load THE UPS IS OPERATING FROM THE BATTERY DE...

Страница 19: ...HOWS ONE OF THE FOLLOWING CODES F04 L04 THE TEMPERATURE OF THE HEATSINKS INSIDE THE UPS IS TOO HIGH Check that the temperature of the environment in which the UPS is located does not exceed 40 C THE B...

Страница 20: ...mance or prevent certain functions from being used CODE DESCRIPTION A06 Sensor1 temperature under 0 C A08 Sensor2 temperature under 0 C A54 Load percentage greater than the user threshold set A61 Repl...

Страница 21: ...he load being powered by the bypass line this procedure is excluded for locks due to serious persistent overloads and short circuits CODE DESCRIPTION L04 Heatsink over temperature L05 Temperature sens...

Страница 22: ...ing 110 load 150 From mains locked after 10 sec From battery locked after 5 sec Load overload 150 From mains locked after 1 sec From battery locked 0 5 sec OTHER DATA Leakage current towards ground mA...

Страница 23: ...0MNVST800RUENUA...

Отзывы: