32
5.7.2 APPLIANCE MAIN ELECTRICAL SUPPLY
INPUT
The appliance is supplied with an electrical fly-lead (approx.
1.5m long) and the 8-poles connector has a link wire inserted
across the TA terminals; these measures enable the basic
function of the appliance once the fly-lead is connected to the
electrical supply. However if this is not suitable, then it is possible
to remove and replace the ‘fly-lead’ with an alternative method
of connection to the electrical supply.
5.7.3 CONNECTING A 230V SUPPLY TO THE
APPLIANCE PCB
WARNING
Isolate the appliance from the electrical supply before
carrying out this procedure
.
Remove the front cover as detailed in section 5.7.1. Locate
the red clip that retains the control panel in the upright position
and move it to the left to release the control panel.
Lower the control panel and remove the two PCB cover retaining
screws (located adjacent to the PCB’s front retaining clips).
Push in the two front clips, and pull out the side clip in order to
release the cover and then remove the cover - lifting from the
front upwards.
The 230v electrical supply input is located at the rear right hand
side of the PCB (see section 8 schematics); disconnect and
remove the factory-fitted fly-lead, and use the same cable-entry
point, route, and respective electrical terminals for the new 230v
supply cable.
NOTE:
ensure that the Earth wire is approximately 30mm
longer that the Live and Neutral wires; and that each terminal
screw is tight.
Carry out any relevant electrical checks as detailed in 8.5
before replacing the PCB cover; ensuring that no cables or
wiring is trapped.
Refit the PCB cover screws and move the control panel back
to the upright position ensuring the red securing clip, clicks
into place.
Replace the appliance front cover as detailed in 5.7.1 paying
attention to the importance of ensuring the cover is providing
an effective seal.
NOTE:
it is the installer and/or electrician’s responsibility
to ensure that the appliance properly earthed. Vokera Ltd.
cannot be held responsible for any damages and/or injuries
that result from the incorrect wiring of the appliance; or from
an ineffective/defective Earth connection.