21
MENU
DEFAULT VALUE FACTORY
SET
MINIMUM
VALUE
MAXIMUM
VALUE
ACCESS LEVEL
NOTES
SET
VALUE
EXHAUST PROBE RESET
INSTALLER
ADD WATER TANK
INSTALLER: only if instantaneous
and “only heating” confi g.
WATER TANK
INSTALLER
REMOVE WATER TANK
INSTALLER
WATER TANK SETPOINT
50°C
37.5°C
60°C
INSTALLER: only if HP enable
to DHW
TANK FROST PROTECT
7°C
0°C
100°C
SERVICE: only if HP enable to
DHW
TANK FR PROT OFFSET
5°C
1°C
20°C
SERVICE: only if HP enable to
DHW
ADD SOLAR PLANT
INSTALLER: only if solar system
is not confi gured
SOLAR
INSTALLER
REMOVE SOLAR PLANT
INSTALLER
T MAX TANK
60°C
10°
130°C
INSTALLER
DELTA T ON PUMP
8°C
DELTA T OFF PUMP
30°C
INSTALLER
DELTA T OFF PUMP
4°C
4°C
DELTA T ON PUMP
INSTALLER
INTEGRATION DELAY
0 min
0 min
180 min
INSTALLER
COLLECTOR T MIN
(- -)
(- -)/-30°C
- -°C
INSTALLER
COLLECTOR T MAX
110°C
COLLECTOR T PROT
180°C
INSTALLER
COLLECTOR T PROT
110°C
80 °C
COLLECTOR T MAX
INSTALLER
COLLECTOR T AUTH
40°C
COLLECTOR T LOCK
95°C
INSTALLER
COLLECTOR T LOCK
35°C
-20°C
COLLECTOR T AUTH
INSTALLER
PWM COLL PUMP
0 min
0 min
30 min
INSTALLER
TANK COOLING
FUNCTION NOT ACTIVE
FUNCTION NOT ACTIVE
FUNCTION ACTIVE
INSTALLER
SOLAR PUMP MODE
OFF
OFF / ON / AUTO
INSTALLER
ADD HEAT PUMP
INSTALLER: only if HP not
confi gured
HEAT PUMP
INSTALLER
ADD HEAT PUMP/REMOVE PDC
INSTALLER: only if HP and boiler
present
USE FREE CONTACTS/USE BUS
USE BUS
USE BUS
USE FREE CONTACT
SERVICE
ENABLE/DISABLE COOLING
FUNCTION NOT ACTIVE
FUNCTION ACTIVE
FUNCTION NOT ACTIVE
INSTALLER
USE FOR DHW/DON’T USE FOR DHW
DHW FUNCTION NOT ACTIVE DHW FUNCTION ACTIVE DHW FUNCTION NOT ACTIVE INSTALLER: if BE17 present
ANTI FREEZE DELTA SET
1°C
0°C
6°C
SERVICE
ENABLE/DISABLE NIGHT REDUCT
FUNCTION NOT ACTIVE
FUNCTION ACTIVE
FUNCTION NOT ACTIVE
INSTALLER
REDUCED FREQUENCY
80%
50%
100%
INSTALLER: if NIGHT
REDUCTION active
NIGHT MODE START TIME
20:00
00:00
23:59
INSTALLER: if NIGHT
REDUCTION active
NIGHT MODE STOP TIME
09:00
00:00
23:59
INSTALLER: if NIGHT
REDUCTION active
MIN OUTDOOR TEMP
5°C
-5°C
20°C
INSTALLER
MIN DHW OUT TEMP
5°C
-5°C
20°C
INSTALLER: only if USE FOR
DHW in HP activated
MIN EMERG OUT T
-10°C
-20°C
10°C and in any case not
over the MIN OUTDOOR
TEMP value
INSTALLER
BOILER INTEGR DELAY
30 min
1 min
240 min
SERVICE
HP INTEGR DELAY
30 min
1 min
240 min
SERVICE
BOILER WAITING
2 min
1 min
60 min
SERVICE
HEAT PUMP WAITING
2 min
1 min
60 min
SERVICE
INTEGRATION OFFSET
5°C
0°C
10°C
SERVICE
WINTER SUMMER DELAY
0h
0h
24h
SERVICE
WARNING VALIDATION
60 sec
1 sec
300 sec
SERVICE
ENABLE CIRC ON/AUTO MODE
AUTO
ON
AUTO
INSTALLER: if boiler in OFF and
AIR PURGING CYCLE not present
DHW HP SETPOINT
60°C
WATER TANK SETPOINT
60°C
SERVICE: only if USE FOR DHW
in HP activated
DHW OFFSET
10°C
0°C
25°C
SERVICE: only if boiler with water
tank with probe and USE FOR
DHW in HP activated
ADD PHOTOVOLTAIC
INSTALLER
PHOTOVOLTAIC
INSTALLER
REMOVE PHOTOVOLTAIC
INSTALLER
ELECTRIC CONVENIENCE
2
0
+10°C
INSTALLER
BACKUP TYPE
1
0
1
INSTALLER
BOOSTER OAT THRESHOLD
-7°C
MIN EMERG OUT T
15°C
INSTALLER