15
EN
b
If the appliance is not used for more than 60 days, it is
necessary to fill the siphon in the boiler. If the boiler is
installed where the ambient temperature can remain above
30°C for prolonged periods, fill the siphon after a period of
30 days of inactivity. The operation must be carried out by
professionally qualified personnel.
5.1 Programmable parameters
A list of the programmable parameters is given below: USER (level al-
ways available) and INSTALLER (access with password 18); for a de-
tailed explanation of the parameters, refer to paragraph
INSTALLER PARAMETERS
Value
min max
Password
level
Value set in
the factory
Personalised
values
CONFIGURATION
301
HYDRAULIC CONFIG.
0
4
INSTALLER
2 *
306
MIN FAN SPEED
1.200
3.600
INSTALLER
see technical data table
307
MAX FAN SPEED
3.700
9.999
INSTALLER
see technical data table
308
SLOW IGNITION ADJUSTMENT
MIN
MAX
INSTALLER
see technical data table
309
MAX CH FAN SPEED
MIN
MAX
INSTALLER
see technical data table
310
RANGE RATED
MIN
MAX_CH
INSTALLER
see technical data table
311
AUX OUTPUT
0
2
INSTALLER
0
312
FLUE GAS COUNTER RESET
0
1
INSTALLER
0
313
IGNITION SPEED IN RESTART AFTER
SHUTDOWN DUE TO TEMPERATURE
MIN FAN SPEED
SLOW IGNITION
ADJUSTMENT
INSTALLER
3.600 rpm
HEATING
405
SET PUMP
NOT APPLICABLE ON THIS MODEL
408
OT+ CASCADE
NOT APPLICABLE ON THIS MODEL
409
SCREED HEATER
0
1
INSTALLER
if boiler in OFF and LT
systems
0
410
HEATING OFF
0 min
20 min
INSTALLER
3 min
411
RESET HEATING TIMES
0
1
INSTALLER
0
415
MAIN LT ZONE
0
1
INSTALLER
0
416
MAX TEMP (MAIN ZONE)
MIN TEMP (MAIN ZONE)
HT: 80.5 - LT: 45.0
INSTALLER
HT: 80.5 - LT: 45.0
417
MIN TEMP (MAIN ZONE)
20
MAX TEMP (MAIN ZONE)
INSTALLER
HT: 40 - LT: 20
418
THERMOREGULATION (MAIN ZONE)
0
1
INSTALLER
if ext. probe present
0
419
CURVE SLOPE (MAIN ZONE)
HT: 1.0 - LT: 0.2
HT: 3.0 - LT: 0.8
INSTALLER
only if 418 = 1
HT 2.0 - LT 0.4
420
NIGHT-TIME COMP. (MAIN ZONE)
0
1
0
432
BUILDING TYPE
5 min
20 min
5 min
433
EXTERNAL PROBE REACTIVITY
0
255
20
DHW
508
MIN DHW TEMP.
37,5 °C
49,0 °C
INSTALLER
37,5°C
509
MAX DHW TEMP.
49,0 °C
60,0 °C
INSTALLER
60,0°C
511
SPEC. DHW FUNCTIONS
0
5
INSTALLER
0
HT. high temperature - LT: low temperature
USER PARAMETERS
Value
min max
Password
level
Value set in
the factory
Personalised
values
SETTINGS
004
MEASUREMENT UNIT
0
1
USER
0
006
BUZZER
0
1
USER
1
SERVICE PARAMETERS
Value
min max
Password
level
Value set in
the factory
Personalised
values
CONFIGURATION
302
PRESSURE TRANSD. TYPE
0
1
SERVICE
1
303
ENABLE FILLING
0
1
SERVICE
0
304
PRESSURE AT START OF FILLING
NOT AVAILABLE ON THIS MODEL
305
VENTING CYCLE
0
1
SERVICE
1
HEATING
401
HIGH TEMP HYSTERESIS OFF
2
10
SERVICE
5
402
HIGH TEMP HYSTERESIS ON
2
10
SERVICE
5
403
LOW TEMP HYSTERESIS OFF
2
10
SERVICE
3
404
LOW TEMP HYSTERESIS ON
2
10
SERVICE
3
b
Some information might not be available depending on the access
level,
machine status or system configuration
.
C
A
B