Operating Instructions and Parts Manual

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

 Pump won't  run

 1. Connections not secure

2. Low or defective battery

3. Float switch stuck

  1.  Check all connections

2.  Check battery and replace if low or defective

3. Make sure nothing is interfering with operation of switch

4. Defective or blown fuse

5. Battery voltage below threshold, 

motor locked out

 4. Check internal fuse located inside the control box. Pull the 

transformer from the wall outlet and remove. If the fuse is 
blown, replace it with a 20 amp automotive type fuse

5. Wait for battery to recharge or replace with fresh battery

Motor hums but 

won't run

1. Defective battery

2. Impeller is locked

1. Check battery and replace if low or defective

2. Unplug pump, remove screen, and check to see if impeller 

is free to turn. If impeller is locked, remove the 7 screws on 
the bottom of the pump to release the housing around the 
impeller. Remove the obstruction. Reassemble pump and 
reconnect

Pump runs but pumps 
very little or no water

1. Check valve missing or 

improperly installed

1. Check to make sure valves installed between primary pump 

discharge and back-up sump pump are functioning properly

2. Obstruction in discharge pipe

3. Discharge length and/or height 

exceeds capacity of pump

4. Low or defective battery

2. Check for obstruction and clear if necessary

3. If discharge is too high, a separate line may be required with 

a lower discharge height

4. Check battery and replace if low or defective

 Pump cyles too frequently

1. Check valve problem

1. Check to make sure valves installed between primary pump 

discharge and back-up sump pump are functioning properly

Power failure light is on 
but A/C power is available

1. Transformer is bad

2. Bad or no connection

3. Branch circuit breaker/fuse blown

1. Replace transformer

2. Check that A/C plug and transformer connection at lid are 

secure

3. Reset breaker or replace fuse

Batteries

 

Dangerous hydrogen gas CAN be

 

released from batteries while charging. 

Sparks CAN ignite the gas in an enclosed space. Wear safety 
goggles when connecting batteries. Battery connections 
SHOULD be made in a well ventilated area. 

 

Working in the vicinity of lead acid

 

batteries CAN be dangerous. Before 

making connections or servicing the batteries, read and follow 
instructions in all applicable instruction manuals. To reduce the 
risk of battery explosion, follow the instructions in this manual 
and those published by the battery manufacturer, as well as 
those of any equipment used in the surrounding area.

 

Never smoke or allow a spark or fl ame

 

in the vicinity of the battery. 

 

Avoid dropping metal tools on the

 

battery posts because they may spark or 

short-circuit the system or battery, causing an explosion. 

Follow battery manufacturer's maintenace procedures and 
schedules. Be certain that the area around the batteries is 
well ventilated. Before servicing the batteries, blow away 
gasses by waving a piece of cardboard near the batteries. 

 

If battery acid contacts your eye(s), fl ush  

 

with cold running water for 10 minutes 

and seek immediate medical attention. If acid contacts your 
eyes, skin or clothing, wash immediately with soap and water. 

Содержание R12V

Страница 1: ... sump pump discharge A ground fault circuit interrupter GFCI is required This pump MUST only be used to pump clear water only This pump is not designed to handle efluent salt water brine laundry discharge or any other application which may cause caustic chemicals and or foreign materials Pump damage MAY occur if used in these applications and WILL void the warranty Battery Information The system i...

Страница 2: ...ng an explosion Installation Installation of this unit may take several hours Before disabling your main pump have ready an appropriate means of evacuating the sump 1 Turn power to main pump off 2 Pump must be instaled using 1 1 4 in or 1 1 2 in rigid PVC piping 2 Operating Instructions and Parts Manual This product contains a chemical that is known to the State of California to cause cancer or bi...

Страница 3: ...r 1 1 2 in PVC Pipe Float Switch 3 R12V Pump Installation The back up pump can be installed with a separate dedicated discharge line Method 1 or tied into an existing sump pump line Method 2 Unplug the existing AC pump Failure to follow this warning COULD result in fatal electric shock 1 Verify that the existing AC pump is in good working order If the AC pump is questionable it is typically recomm...

Страница 4: ... to accomodate a second pump 9 Glue a 45º elbow to the short pipe on the back up pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method 2 10 Glue a short piece of PVC pipe between the 45º elbow and the Y NOTE Check valves can be placed directly in the pump discharge if desired However for ease of disassembly it is recommended that check valves be placed ab...

Страница 5: ... or defective Red blinking Battery discharged below level where pumping can occur Motor is locked out by controller until battery is sufficiently charged to run pump d Plug in transformer and main AC pump When main AC power is out and when pump has been running the lights will indicate battery status 4 A chirping sound from the control box will accompany the red light indicating that the battery m...

Страница 6: ...ce if low or defective Pump cyles too frequently 1 Check valve problem 1 Check to make sure valves installed between primary pump discharge and back up sump pump are functioning properly Power failure light is on but A C power is available 1 Transformer is bad 2 Bad or no connection 3 Branch circuit breaker fuse blown 1 Replace transformer 2 Check that A C plug and transformer connection at lid ar...

Страница 7: ...ress any correspondence to Model number RIDGID PUMPS Serial number if any 101 Production Drive Part description and number as shown in parts list Harrison OH 45030 U S A Reference Number Description Part Number Quantity 1 Transformer 30221 WYN1 1 2 Pump 58324 WYN1 1 3 Lid Assembly 60184 WYN1 1 1 2 3 7 R12V ...

Страница 8: ...t alteration improper installation or maintenance modification repair by other than a service center authorized to repair RIDGID brand water pumps or failure to operate in accordance with RIDGID water pump written instructions WAYNE WATER SYSTEMS MAKES NO OTHER EXPRESS WARRANTIES REPRESENTATIONS OR PROMISES AS TO THE QUALITY OR PERFORMANCE OF ITS WATER PUMPS OTHER THAN THOSE SPECIFICALLY STATED IN...

Страница 9: ...anipular la batería debe protegerse los ojos Debe utilizar una válvula de chequeo en el orificio de descarga de la bomba principal parasumideros Se requiere un interruptor con dispositivo para desconexión automática en caso de fallas Esta bomba sólo debe usarse para bombear aguas limpias Esta bomba no está diseñada para bombear efluentes agua salada salmuera agua con detergentes o en ningún otro l...

Страница 10: ...sea utilizar tubería de descarga de 11 4 pulg NPT 3 2 cm será necesario instalar un adaptador no incluido Las tuberías de diámetro más pequeño reducirán el flujo la velocidad y el rendimiento de la bomba 10 Sp Manual de Instrucciones de Operación y Piezas Figura 1 Método 1 3 Corte una sección de 4 pies de 3 18 cm 11 4 pulg o de 3 81 cm 11 2 pulg de diámetro de un tubo de PVC rígido Pegue el tubo d...

Страница 11: ... que ajustarse para contener una segunda bomba 9 Pegue un codo de 45º al tubo corto en la bomba R12V Pegue un adaptador en Y al tubo corto en la bomba existente como se muestra en la ilustración del Método 2 10 Pegue un tramo corto de tubo de PVC entre el codo de 45º y la Y NOTA Las válvulas de retención pueden colocarse Figure 2 Método 2 directamente en la descarga de la bomba si lo desea Sin emb...

Страница 12: ...tor está bloqueado por el controlador hasta que la batería esté suficientemente cargada para activar la bomba d Conecte la bomba principal y el cargador al tomacorrientes Si la corriente alterna está apagada mientras la bomba está funcionando la luz le indicará la carga de la batería 4 Al escuchar un sonido cuando la luz roja se enciende le indica que necesita revisar o reemplazar la batería El vo...

Страница 13: ...re atención médica de inmediato Si el ácido entra en contacto con su piel o su vestimenta lávese inmediatamente con agua y jabón Nunca fume ni deje que haya chispas ni llamas en el área próxima a la batería Evite dejar caer herramientas de metal sobre los bornes de la batería porque pueden causar chispas o un cortocircuito en el sistema o en la batería provocando una explosión Siga los procedimien...

Страница 14: ...iberar la caja que cubre el impulsor Retire la obstrucción Vuelva a armar la bomba y vuelva a conectar La bomba funciona pero bombea poca o nada de agua 1 Revise la válvula que falta o que está mal instalada 1 Revise para asegurarse de que las válvulas de retención instaladas entre la bomba primaria y la bomba de respaldo para sumideros estén funcionando adecuadamente 2 Obstrucción en el tubo de d...

Страница 15: ...01 Production Drive Harrison OH 45030 U S A 1 Cargador 30221 WYN1 1 2 Bomba 58324 WYN1 1 3 Conjunto de cubierta protectora 60184 WYN1 1 No de Ref Descripción Número de pieza Ctd Sírvase proporcionar la siguiente información Número del modelo Número de serie de haberlo Descripciones y número de piezas tal como aparecen en la lista de piezas 1 2 3 15 Sp R12V ...

Страница 16: ...iento inadecuados modificación reparación por una persona que no esté autorizada por el centro de servicio para reparar bombas de agua de la marca RIDGID o la incapacidad de funcionar de acuerdo con las instrucciones escritas de la bomba de agua RIDGID WAYNE WATER SYSTEMS NO PROPORCIONA NINGUNA GARANTÍA REPRESENTACIÓN NI PROMESA EXPRESA SOBRE LA CALIDAD O EL FUNCIONAMIENTO DE SUS BOMBAS DE AGUA EX...

Отзывы: