4.   Test pump operation by filling the sump with water
      while the main pump is unplugged. If the pump
      operates properly, plug the transformer into the GFCI
      protected outlet to begin charging the battery.

5.   Protect electrical cord from sharp objects, hot surfaces,
      oil and chemicals. Avoid kinking the cord and replace
      damaged components immediately. 

Operation

 

Always disconnect the power 

  source before attempting 

to install, service, relocate or maintain the pump. 
NEVER touch sump pump motor, water or discharge 
piping when pump is connected to electrical power. 
NEVER handle a pump or pump motor with wet hands or when 
standing on wet or damp surface or in water. Fatal electric 
shock COULD occur.

 

Risk of electrical shock! Usea 

  GFCI receptacle to reduce the 

risk of fatal electric shock. Cutting the cord WILL 
void the warranty and make the pump inoperable. 

1.   After installation, the back-up pump will start                  
      when the water level rises above the depth that                 
      the primary pump should start.

2.   The control box has a DC charger designed to
      shorten the recharging time of your battery, and to
      prevent overcharging. In addition, the control box has
      a time delay which keeps the pump from repeated,
      short cycles when it shuts off. The time delay feature
      will allow the pump to run 20-25 seconds after the
      switch reaches the off position.

3.  

 

The control box contains multi-colored indicator

      lights. When AC power is present, the lights will
      indicate the charging state, and not reflect actual
      battery voltage, particularly with a defective battery. In
      order for the indicator light to provide an accurate
      reading, steps "a" through "d" must be followed.

 

Unplug main AC pump and the

 

transformer. Risk of electrical shock!

a.   After main pump and transformer are unplugged, a
      power off alert tone will sound for 30 seconds.

 

b.   Lift and release the fl oat switch to activate the back
      up pump.

 

 

 

c.   When the pump stops, read the charge indicator lights:

      

Green

: Indicates the battery is fully charged.

      

Yellow

: Indicates battery is partially charged, but still

      operable.
      

Red

: Battery is completely discharged or defective. 

     

 Red blinking:

 Battery discharged below level where

      pumping can occur. Motor is locked out by controller
      until battery is sufficiently charged to run pump.

d.   Plug in transformer and main AC pump.

When main AC power is out, and when pump has been 
running, the lights will indicate battery status.

4.   A chirping sound from the control box will accompany
      the red light, indicating that the battery may require
      attention or replacement. Voltage is only an indicator
      of battery condition and may not reflect the true
      condition of the battery. See maintenance for
      instruction on assessing battery condition.

  

5.   A single thirty (30) second tone will sound when
     power to the system is interrupted and the power
     failure light will illuminate. The unit will reset and the
     light will go out automatically when power is restored. 

6.  A three (3) second tone will sound every time the pump
     starts.    

Maintenance

 

Always disconnect the

 

electrical supply before 

attempting to install, service or relocate or perform 
any maintenance. If the power source is out of sight, 
lock and tag in the open (off) position to prevent 
unexpected power application. Failure to do so COULD result in 
fatal electric shock. Only qualifi ed electricians should repair this 
unit. Improper repair COULD result in fatal electric shock.

 

Once a month, check the battery    

 

condition. To check battery condition 

follow steps listed below:

1.   Unplug the transformer.

2.   For batteries with top caps that can be removed, the 
electrolyte level should be checked and filled tomanufacturer's 
specifications. The charge for each cell
should be checked with a hydrometer. A gravity of 1.265 
indicates the battery is at full charge. If the
specific gravity of any of the cells varies more than
.050, the battery should be replaced. 

NOTE

: An inexpensive hydrometer can be purchased at an 

automotive parts dealer. 

3.   Inspect the terminals and clamps for corrosion and
      tightness. Clean and tighten as required. 

4.   Unplug the main pump and fill sump with water until
      back-up pump turns on. Repeat process two times to
      make sure pump is operating normally. 

5.   If pump operates normally, plug transformer into
      wall outlet, turn on main pump. If pump fails to
      operate normally, see Troubleshooting guide and
      correct problem. Repeat step 5.

 

5

R12V

Содержание R12V

Страница 1: ... sump pump discharge A ground fault circuit interrupter GFCI is required This pump MUST only be used to pump clear water only This pump is not designed to handle efluent salt water brine laundry discharge or any other application which may cause caustic chemicals and or foreign materials Pump damage MAY occur if used in these applications and WILL void the warranty Battery Information The system i...

Страница 2: ...ng an explosion Installation Installation of this unit may take several hours Before disabling your main pump have ready an appropriate means of evacuating the sump 1 Turn power to main pump off 2 Pump must be instaled using 1 1 4 in or 1 1 2 in rigid PVC piping 2 Operating Instructions and Parts Manual This product contains a chemical that is known to the State of California to cause cancer or bi...

Страница 3: ...r 1 1 2 in PVC Pipe Float Switch 3 R12V Pump Installation The back up pump can be installed with a separate dedicated discharge line Method 1 or tied into an existing sump pump line Method 2 Unplug the existing AC pump Failure to follow this warning COULD result in fatal electric shock 1 Verify that the existing AC pump is in good working order If the AC pump is questionable it is typically recomm...

Страница 4: ... to accomodate a second pump 9 Glue a 45º elbow to the short pipe on the back up pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method 2 10 Glue a short piece of PVC pipe between the 45º elbow and the Y NOTE Check valves can be placed directly in the pump discharge if desired However for ease of disassembly it is recommended that check valves be placed ab...

Страница 5: ... or defective Red blinking Battery discharged below level where pumping can occur Motor is locked out by controller until battery is sufficiently charged to run pump d Plug in transformer and main AC pump When main AC power is out and when pump has been running the lights will indicate battery status 4 A chirping sound from the control box will accompany the red light indicating that the battery m...

Страница 6: ...ce if low or defective Pump cyles too frequently 1 Check valve problem 1 Check to make sure valves installed between primary pump discharge and back up sump pump are functioning properly Power failure light is on but A C power is available 1 Transformer is bad 2 Bad or no connection 3 Branch circuit breaker fuse blown 1 Replace transformer 2 Check that A C plug and transformer connection at lid ar...

Страница 7: ...ress any correspondence to Model number RIDGID PUMPS Serial number if any 101 Production Drive Part description and number as shown in parts list Harrison OH 45030 U S A Reference Number Description Part Number Quantity 1 Transformer 30221 WYN1 1 2 Pump 58324 WYN1 1 3 Lid Assembly 60184 WYN1 1 1 2 3 7 R12V ...

Страница 8: ...t alteration improper installation or maintenance modification repair by other than a service center authorized to repair RIDGID brand water pumps or failure to operate in accordance with RIDGID water pump written instructions WAYNE WATER SYSTEMS MAKES NO OTHER EXPRESS WARRANTIES REPRESENTATIONS OR PROMISES AS TO THE QUALITY OR PERFORMANCE OF ITS WATER PUMPS OTHER THAN THOSE SPECIFICALLY STATED IN...

Страница 9: ...anipular la batería debe protegerse los ojos Debe utilizar una válvula de chequeo en el orificio de descarga de la bomba principal parasumideros Se requiere un interruptor con dispositivo para desconexión automática en caso de fallas Esta bomba sólo debe usarse para bombear aguas limpias Esta bomba no está diseñada para bombear efluentes agua salada salmuera agua con detergentes o en ningún otro l...

Страница 10: ...sea utilizar tubería de descarga de 11 4 pulg NPT 3 2 cm será necesario instalar un adaptador no incluido Las tuberías de diámetro más pequeño reducirán el flujo la velocidad y el rendimiento de la bomba 10 Sp Manual de Instrucciones de Operación y Piezas Figura 1 Método 1 3 Corte una sección de 4 pies de 3 18 cm 11 4 pulg o de 3 81 cm 11 2 pulg de diámetro de un tubo de PVC rígido Pegue el tubo d...

Страница 11: ... que ajustarse para contener una segunda bomba 9 Pegue un codo de 45º al tubo corto en la bomba R12V Pegue un adaptador en Y al tubo corto en la bomba existente como se muestra en la ilustración del Método 2 10 Pegue un tramo corto de tubo de PVC entre el codo de 45º y la Y NOTA Las válvulas de retención pueden colocarse Figure 2 Método 2 directamente en la descarga de la bomba si lo desea Sin emb...

Страница 12: ...tor está bloqueado por el controlador hasta que la batería esté suficientemente cargada para activar la bomba d Conecte la bomba principal y el cargador al tomacorrientes Si la corriente alterna está apagada mientras la bomba está funcionando la luz le indicará la carga de la batería 4 Al escuchar un sonido cuando la luz roja se enciende le indica que necesita revisar o reemplazar la batería El vo...

Страница 13: ...re atención médica de inmediato Si el ácido entra en contacto con su piel o su vestimenta lávese inmediatamente con agua y jabón Nunca fume ni deje que haya chispas ni llamas en el área próxima a la batería Evite dejar caer herramientas de metal sobre los bornes de la batería porque pueden causar chispas o un cortocircuito en el sistema o en la batería provocando una explosión Siga los procedimien...

Страница 14: ...iberar la caja que cubre el impulsor Retire la obstrucción Vuelva a armar la bomba y vuelva a conectar La bomba funciona pero bombea poca o nada de agua 1 Revise la válvula que falta o que está mal instalada 1 Revise para asegurarse de que las válvulas de retención instaladas entre la bomba primaria y la bomba de respaldo para sumideros estén funcionando adecuadamente 2 Obstrucción en el tubo de d...

Страница 15: ...01 Production Drive Harrison OH 45030 U S A 1 Cargador 30221 WYN1 1 2 Bomba 58324 WYN1 1 3 Conjunto de cubierta protectora 60184 WYN1 1 No de Ref Descripción Número de pieza Ctd Sírvase proporcionar la siguiente información Número del modelo Número de serie de haberlo Descripciones y número de piezas tal como aparecen en la lista de piezas 1 2 3 15 Sp R12V ...

Страница 16: ...iento inadecuados modificación reparación por una persona que no esté autorizada por el centro de servicio para reparar bombas de agua de la marca RIDGID o la incapacidad de funcionar de acuerdo con las instrucciones escritas de la bomba de agua RIDGID WAYNE WATER SYSTEMS NO PROPORCIONA NINGUNA GARANTÍA REPRESENTACIÓN NI PROMESA EXPRESA SOBRE LA CALIDAD O EL FUNCIONAMIENTO DE SUS BOMBAS DE AGUA EX...