144
Ti-P1 Training
Slide 144
2. Energy Saving
2.3 Energy Save Effectiveness – 2
(1) At the start of the measurement period, read the values of
SP 8941:001-005 (Machine Status), measured in minutes.
(2) At the end of the measurement period,read the values of
SP 8941:001-005 (Machine Status), measured in minutes.
(3) Find the amount of time spent in each mode.
(Subtract the earlier measurement from the later
measurement and convert the result to hours.)
(4) Power consumption figures for each model are acquired
from “Publication System of MSDS_&_PEI (PRODUCT
ENVIRONMENT INFORMATION)” database.
Example:
1W max
Sleep mode
20W max
Low power mode
51W / 1W max
Ready mode / Energy Save
NA: 543W, EU: 565W
Operating mode
Power consumption:
Mode/condition
Low power mode (fusing off mode) is disabled by default. It can be enabled
with a user tool.