100
Ti-P1 Training
Slide 100
Installing a New ITB Unit
Print out the logging data using SP5-990-004
before you replace the part.
The counter for the Image Transfer Belt Unit
must be reset after installing a new one.
1. Execute SP7-804-017 and SP7-804-060
2. Turn off the power of the machine, and then turn
it back on.
This only applies to parts installed by service
technicians.
The part for replacement by users has a new unit
detection mechanism.
If you are replacing the image transfer belt unit
SP7-804-017 (PM Counter Clear ITB Unit)
SP7-804-060 (PM Counter Clear Life: ITB Unit)
If you are replacing the image transfer belt unit, you should execute SP7-
804-017, for correct control depending on the rotation distance. But, if you
execute only SP7-804-017, the counter for displaying the unit life is not
cleared. So you must also clear the counter by executing SP7-804-060 (PM
Counter Clear Life: ITB Unit).