101
Ti-P1 Training
Slide 101
Installing a New Paper Transfer Roller
Print out the logging data using SP5-990-004
before you replace the part.
The counter for the Paper Transfer Roller must
be reset after installing a new one.
1. Execute SP7-804-022 and SP7-804-061
2. Turn off the power of the machine, and then turn
it back on.
This only applies to replacement by service
technicians.
The Paper Transfer Roller as a supply part is
kitted together with the Image Transfer Belt unit
and does not require counter reset, since it will
be replaced at the same time as the Image
Transfer Belt Unit.
If you are replacing the paper transfer roller
SP7-804-022 (PM Counter Clear PTR Unit)
SP7-804-061 (PM Counter Clear Life: PTR Unit)
If you are replacing the paper transfer roller, you should execute SP7-804-
022, for correct control depending on the rotation distance. But, if you
execute only SP7-804-022, the counter for displaying the unit life is not
cleared. So you must also clear the counter by executing SP7-804-061 (PM
Counter Clear Life: PTR Unit).