PE-MF3/PE-P2 Training
Slide 149
Fusing Temperature Control - 2/3
The center thermistor controls the fusing temperature.
The above chart shows the relationship between temperature and fusing
belt rotation.
No rotation
Rotation till
6 s after printing
No rotation
Rotation till
3 s after ready
No
rotation
Sleep mode
Prints
10
minutes
1st print time: 14 s
10 s recovery
temperature (150
°
C)
Warm-up time: 30 s
(Switch ON to Ready condition)
173
℃
(Ready temp)
155
°
℃
(Standby temp)
80
°
C
(Rotation start
temp)
Center
thermistor
temp (
°
C)
Time (seconds)
Energy
Saver 1
No additional notes
Содержание M095
Страница 42: ...42 PE MF3 PE P2 Training Slide 42 Service Training M099 M100 M095 M096 Installation No additional notes ...
Страница 45: ...45 PE MF3 PE P2 Training Slide 45 Service Training M099 M100 M095 M096 Service Mode No additional notes ...
Страница 53: ...53 PE MF3 PE P2 Training Slide 53 Service Training M099 M100 M095 M096 Maintenance No additional notes ...
Страница 58: ...58 PE MF3 PE P2 Training Slide 58 Service Training M099 M100 M095 M096 Machine Overview No additional notes ...
Страница 69: ...69 PE MF3 PE P2 Training Slide 69 Original Feed Path 1 Original feed path ...
Страница 92: ...92 PE MF3 PE P2 Training Slide 92 Service Training M099 M100 M095 M096 Laser Unit No additional notes ...
Страница 104: ...104 PE MF3 PE P2 Training Slide 104 Service Training M099 M100 M095 M096 AIO Cartridge No additional notes ...
Страница 116: ...116 PE MF3 PE P2 Training Slide 116 Service Training M099 M100 M095 M096 Paper Feed No additional notes ...
Страница 125: ...125 PE MF3 PE P2 Training Slide 125 Service Training M099 M100 M095 M096 Image Transfer No additional notes ...
Страница 141: ...141 PE MF3 PE P2 Training Slide 141 Service Training M099 M100 M095 M096 Fusing No additional notes ...
Страница 153: ...153 PE MF3 PE P2 Training Slide 153 Stripper Pawl Solenoid This is a new component for this series No additional notes ...
Страница 184: ...184 PE MF3 PE P2 Training Slide 184 No additional notes ...