Process Control
Process Control Flow
Process control adjusts imaging processing conditions as required to maintain constant, uniform image
density. Process control comprises toner coverage control and MUSIC (Mirror Unit Skew and Interval
Correction) which ensures consistent color overlay.
Toner Coverage Control
1.
The machine uses the temperature and humidity readings of the temperature/humidity sensor to
determine the correct bias for the application of charge to the surface of the drum to ensure that
the surface potential of the drum remains constant.
2.
The machine creates differ toner patch patterns on the surface of the image transfer belt by varying
the bias charge, and then the TM/P sensor detects the amount of toner coverage in each patch to
determine the target development bias for optimum toner coverage. This is toner coverage process
control.
3.
Next, a range of halftone toner patches are created on the image transfer belt by varying the
strength of LD exposures, the densities of these images are detected by the TM/P sensor, and then
the machine determines optimum LD power levels for creating the optimum densities for halftone
images. This is halftone process control.
MUSIC
In the MUSIC phase, first correction patterns are generated on the image transfer belt then the TM/P
sensors read the patterns. The machine uses these readings to measure and then correct the
positioning of the images exposed on the image transfer belt. (Refer to,
TM/P Sensors
Three TM/P sensors are on a single board. The center sensor acts as an ID sensor and a MUSIC
sensor. The left and right sensors are used only for MUSIC.
Содержание M C250FW
Страница 2: ......
Страница 8: ......
Страница 12: ......
Страница 34: ...3 Preventive Maintenance 22 to remove any remaining moisture ...
Страница 45: ...4 Replacement and Adjustment 33 6 Release the belt A and then remove the front cover unit B ...
Страница 103: ...4 Replacement and Adjustment 91 MF model 11 Remove the fusing transport drive unit A ...
Страница 112: ...4 Replacement and Adjustment 100 MF model 8 Remove the belt cover A ...
Страница 114: ...4 Replacement and Adjustment 102 12 On the MF model only remove the FFC harness guide A 13 Remove the duplex motor M5 A ...
Страница 117: ...4 Replacement and Adjustment 105 MF model 3 On the MF model only remove the USB dongle A and interface cover B ...
Страница 123: ...4 Replacement and Adjustment 111 MF model 3 On the MF model only remove the USB dongle A and interface cover B ...
Страница 183: ...5 System Maintenance 171 8 Press OK on the screen or press on the number keys to exit ...
Страница 188: ...5 System Maintenance 176 Special Sender List Configuration Page Printer model ...
Страница 189: ...5 System Maintenance 177 MF model ...
Страница 191: ...5 System Maintenance 179 MF model The following contents can be confirmed in the Maintenance Report ...
Страница 260: ...6 Troubleshooting 248 Flowchart ...
Страница 271: ...7 Detailed Descriptions 259 ...
Страница 297: ...7 Detailed Descriptions 285 Boards Block Diagram Printer Model ...
Страница 301: ......