5.1 SERVICE PROGRAM MODE
1. Service Program Access Procedure
Function
For service
representatives
For sales representatives and
customers
Remarks
Access SP
mode
TURN ON
DPS101-2 ON
THE MAIN
BOARD.
+
"00" WILL BE
DISPLAYED IN THE
MAG. RATIO
INDICATOR.
CLEAR/STOP
"0" AND "1" WILL
BLINK ALTERNATELY
IN THE COPY
COUNTER.
Select the
SP mode
number
RECALL/ ENTER
ENTER THE DESIRED SP MODE
NUMBER USING THE NUMBER KEYS.
THE SP MODE
NUMBER AND "1"
WILL BLINK
ALTERNATELY IN THE
COPY COUNTER.
RECALL/ ENTER
Change the
setting
PRESS THE "0" OF THE NUMBER
KEYS WHEN YOU WISH TO CHANGE
THE SETTING OF THAT MODE.
THE DATA CHANGES
AS FOLLOWS:
→
10
→
11
→
10
→
11
→
....
Store the
setting
RECALL/ENTER
Reset the
SP mode
number
CLEAR/STOP
"0" AND "1" WILL
BLINK ALTERNATELY
IN THE COPY
COUNTER.
Leave SP
mode
TURN OFF THE
DPS101-2 ON
THE MAIN
BOARD.
ENERGY SAVER/CLEAR MODES
"100%" WILL BE
DISPLAYED IN THE
MAG. RATIO
INDICATOR.
ENERGY SAVER
/CLEAR MODES
CLEAR STOP
(TO GO TO
ANOTHER SP
MODE.)
- 93 -
Содержание FT5034
Страница 1: ...SERVICE MANUAL FT5034C...
Страница 3: ...1 INSTALLATION 1 1 INSTALLATION REQUIREMENTS 3 1 2 INSTALLATION PROCEDURE 4 2...
Страница 8: ...2 OVERVIEW 2 1 SPECIFICATIONS 8 2 2 GUIDE TO COMPONENTS 9 7...
Страница 10: ...2 2 GUIDE TO COMPONENTS 1 Operation Panel 9...
Страница 11: ...2 Indicator Panel 10...
Страница 12: ...3 COPY PROCESS 3 1 COPY PROCESS DIAGRAM 12 11...
Страница 93: ...5 SP MODE DIP SW TABLES 5 1 SERVICE PROGRAM MODE 93 5 2 DIP SWITCH TABLES 96 5 3 INPUT CHECK MODE 97 92...
Страница 99: ...6 CALL SERVICE CONDITIONS 6 1 CALL SERVICE CONDITION CODES 91 6 2 CALL SERVICE CONDITION DETAILS 92 98...
Страница 115: ...8 TROUBLESHOOTING 114...