2. Toner Density Control
The main CPU checks toner density by directly detecting the image density at the
beginning of the first copy cycle after the main switch is turned on, and at every 10th
copy after that.
When the image density is too low, the CPU activates the toner supply clutch to add
a selected amount of toner over the next 10 copy cycles.
During image density detection cycles, the center block of the erase lamps turns off
(A5 Lengthwise size) long enough for the sensor pattern to be developed. When the
sensor pattern image on the drum is over the ID sensor, the LED of the ID sensor
turns on and the light reflected off the sensor pattern image is checked by the ID
sensor (which is a photosensor). While the sensor pattern is being developed, the
bias voltage is set at 470 volts.
Full Erase
A5 Lengthwise
Full Erase
Leading Edge Erase
Sensor Pattern
Original Lead Edge
Original
Low Toner
[Low Toner]
Enough Toner
[Enough Toner]
PTL
Image Density
Sensor
Developed Sensor
Pattern Image
- 63 -
Содержание FT5034
Страница 1: ...SERVICE MANUAL FT5034C...
Страница 3: ...1 INSTALLATION 1 1 INSTALLATION REQUIREMENTS 3 1 2 INSTALLATION PROCEDURE 4 2...
Страница 8: ...2 OVERVIEW 2 1 SPECIFICATIONS 8 2 2 GUIDE TO COMPONENTS 9 7...
Страница 10: ...2 2 GUIDE TO COMPONENTS 1 Operation Panel 9...
Страница 11: ...2 Indicator Panel 10...
Страница 12: ...3 COPY PROCESS 3 1 COPY PROCESS DIAGRAM 12 11...
Страница 93: ...5 SP MODE DIP SW TABLES 5 1 SERVICE PROGRAM MODE 93 5 2 DIP SWITCH TABLES 96 5 3 INPUT CHECK MODE 97 92...
Страница 99: ...6 CALL SERVICE CONDITIONS 6 1 CALL SERVICE CONDITION CODES 91 6 2 CALL SERVICE CONDITION DETAILS 92 98...
Страница 115: ...8 TROUBLESHOOTING 114...