4. Vsp Variation
The following diagram shows the variation factors which affect Vsp and their results.
5. ID Sensor
1. When SP mode (54) is changed to "11", the LED of the ID sensor turns on.
Consequently, Vsg is measured at TP103 (ID sensor output) and TP101 (GND).
(Vsg can be adjusted by VR101.)
Vsg can also be monitored on the LCD display through SP mode.
(low)
1. Charge
(high)
(strong)
2. Exposure
(weak)
(rapid)
3. Drum Sensitivity
(slow)
(high)
4. Development Bias
(low)
light
dark
high
low
supplied
no supplied
high
low
return to the
original condition
<Variation Factor> <Image Density> <Vsp> <Toner Supply> <Toner Density> <Vsp Image Density>
•
If we change the output of the C/B power pack or
the lamp regulator, the image density detected by
the ID sensor also returns to the original
condition. But this may cause toner scattering or
carrier attraction to the drum because the toner
density of the developer is changed.
ID sensor LED
ID sensor
output
- 66 -
Содержание FT5034
Страница 1: ...SERVICE MANUAL FT5034C...
Страница 3: ...1 INSTALLATION 1 1 INSTALLATION REQUIREMENTS 3 1 2 INSTALLATION PROCEDURE 4 2...
Страница 8: ...2 OVERVIEW 2 1 SPECIFICATIONS 8 2 2 GUIDE TO COMPONENTS 9 7...
Страница 10: ...2 2 GUIDE TO COMPONENTS 1 Operation Panel 9...
Страница 11: ...2 Indicator Panel 10...
Страница 12: ...3 COPY PROCESS 3 1 COPY PROCESS DIAGRAM 12 11...
Страница 93: ...5 SP MODE DIP SW TABLES 5 1 SERVICE PROGRAM MODE 93 5 2 DIP SWITCH TABLES 96 5 3 INPUT CHECK MODE 97 92...
Страница 99: ...6 CALL SERVICE CONDITIONS 6 1 CALL SERVICE CONDITION CODES 91 6 2 CALL SERVICE CONDITION DETAILS 92 98...
Страница 115: ...8 TROUBLESHOOTING 114...