28 February 1989
4.16 DC POWER SUPPLY FUSES
- Conditions -
1. Fuse 1 open - no power supply output
2. Fuse 2 open - no +24 Vaa output
3. Fuse 3 open - no +24 Vpp output
- Phenomena -
1,2. Indicators on the operation panel stay off when the main switch is turned
on.
3. Copies are blank.
NOTE: Check the power pack if Fuse 3 blows after it is replaced.
4.17 SHORT CIRCUIT IN DC 5V LINE
- Phenomenon -
Indicators on the operation panel stay off when the main switch is turned on.
- Action -
Remove units that have 5V lines one at a time to determine which unit has the
shorted line. (The operation panel indicators will turn on when the unit with the
defective line is removed.)