21 April 1989
6.11 DRUM CURRENT ADJUSTMENT (SP Mode #9-5&7)
Transfer
DC - 18.0 ± 1.5
VR-2
Separation
AC 44 ± 2.0
DC +1.5 ± 1.5
VR AC
VR DC }
SC Power Pack
NOTE: The above values are measured with the Beckman 330 or 3030.
1. Turn off the main switch and remove the following parts:
Charge corona unit
Cleaning unit
Development units (black and color)
Drum unit.
2. Remove the paper guide from the transfer corona unit.
3. Clean the transfer/separation corona wires.
4. Turn on the front door safety switch.
5. Turn ON DIP switch 1 - 4.
6. Remove the drum from the drum unit.
7. Set the drum shoe [A] and connect the multimeter as follows:
a) Slide the drum unit onto the drum unit guide rail.
b) Put the drum shoe and the drum adaptor on the drum shaft
(A006 9105) [B] and attach the drum knob.
c)
Set the drum shaft in the drum unit.
d) Connect the drum shoe and multimeter leads as shown.
5-90
Содержание FT4460
Страница 1: ...RICOH R I C O H F T 4 4 6 0 RICOH COMPANY LTD...
Страница 19: ...SECTION 1 OVERALL M A C H I N E INFORMATION...
Страница 29: ...28 February 1989 3 COPY PROCESSES AROUND THE DRUM...
Страница 30: ...28 February 1989 4 FUNCTIONAL OPERATION 1 10...
Страница 38: ...28 February 1989 7 MECHANICAL COMPONENT LAYOUT...
Страница 49: ...SECTION 2 DETAILED SECTION D E S C R I P T I O N S...
Страница 136: ...Section 2 Timing Chart following page...
Страница 137: ......
Страница 138: ...S E C T I O N 3...
Страница 158: ...SERVICE T A B L E S...
Страница 212: ...REPLACEMENT AND...
Страница 334: ...SECTION 12...
Страница 398: ...Water Proof Pocket Electrical Component Layout Page 401 406 Connector Layout Page 407 412 Point to Point Page 413 415...
Страница 399: ......
Страница 411: ......
Страница 412: ......
Страница 413: ......