4. SERVICE PROGRAM MODE
4.1 DIP SWITCHES TABLES
4.1.1 DIP SW 1 (Operation Panel)
*
**
SW #
1*
2 **
3
4
Description
Free run
Forced start (Ready temperature bypass)
Clear counter (see CLEAR MEMORY PROCEDURE)
Service Program mode access
When ON, the SP mode is disabled.
The copy quality and transport ability cannot be guaranteed until the
fusing temperature reaches the standard level.
4-11