28 February 1989
1.14 MARKS AT 251 MM INTERVALS
- Phenomenon -
Imperfections in the copy image
appear at 251 mm intervals.
- Possible Causes -
1.
2.
Scratches or areas of reduced sensitivity on the drum (Drum diameter:
80 mm).
If a positive image remains at 251 mm intervals, a dirty quenching lamp
filter or a defective quenching lamp may be the problem.
- Actions -
1. Replace the drum.
(Set SP Mode No. 66 to initialize the drum.)
2. Clean the quenching lamp filter and/or replace the quenching lamp.
12-19