System Service Mode (F/SPF: D068/D069)
D067/D068/D069/D072 5-22
SM
Appendix
Sharpness-Low ID
[–2 to 2 /
0
/ 1/step]
4932*
Adjust the clarity. This setting is only applied to the originals in SP4-921.
001 Copy
002 Fax
003 Scanner
4935*
Color Image Adjust
Main Scan MTF Level
[0 to 3 /
0
/ 1/step]
001 Adjust the MTF level for the main scan. This setting is only activated for the
specified mode with SP4-921-004.
0: None, 1: Weak, 2: Middle, 3: Strong
Main Scan MTF Strength
[0 to 5 /
0
/ 1/step]
002 Adjust the MTF strength for the main scan. This setting is only activated for
the specified mode with SP4-921-004.
0: 1, 1: 1/32, 2: 1/16, 3: 1/8, 4: 1/4, 5: 1/2
Sub Scan MTF Level
[0 or 1 /
0
/ 1/step]
003 Turns on or off the MTF for the sub scan. This setting is only activated for the
specified mode with SP4-921-004.
0: No, 1: Yes
Sub Scan MTF Strength
[0 to 5 /
0
/ 1/step]
004 Adjust the MTF strength for the sub scan. This setting is only activated for the
specified mode with SP4-921-004.
0: 1, 1: 1/32, 2: 1/16, 3: 1/8, 4: 1/4, 5: 1/2
Содержание D067
Страница 1: ...D067 D068 D069 D072 SERVICE MANUAL 004356MIU ...
Страница 2: ......
Страница 3: ...D067 D068 D069 D072 SERVICE MANUAL ...
Страница 4: ......
Страница 5: ...D067 D068 D069 D072 SERVICE MANUAL 004356MIU ...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 21: ......
Страница 23: ......
Страница 28: ......
Страница 29: ...PRODUCT INFORMATION ...
Страница 30: ......
Страница 46: ...D067 D068 D069 D072 16 SM INSTALLATION ...
Страница 88: ...Printer Scanner Unit D067 D068 D069 D072 2 42 SM ...
Страница 110: ...PREVENTIVE MAINTENANCE ...
Страница 113: ...REPLACEMENT ADJUSTMENT ...
Страница 114: ......
Страница 130: ...Fusing D067 D068 D069 D072 4 16 SM 4 5 2 EXIT SENSOR 1 Fusing unit Fusing Unit 2 Exit sensor A x 1 ...
Страница 138: ...PCU and Quenching Lamp D067 D068 D069 D072 4 24 SM 4 6 2 QUENCHING LAMP 1 PCU PCU 2 Quenching lamp A x 1 ...
Страница 183: ......
Страница 184: ...TROUBLESHOOTING ...
Страница 191: ......
Страница 222: ...DO67 D068 D069 D072 SERVICE MANUAL APPENDICES ...
Страница 223: ......
Страница 228: ...APPENDIX SPECIFICATIONS ...
Страница 229: ......
Страница 248: ...APPENDIX PREVENTIVE MAINTENANCE TABLES ...
Страница 249: ......
Страница 253: ......
Страница 254: ...APPENDIX SERVICE CALL CONDITIONS ...
Страница 255: ......
Страница 302: ...APPENDIX ELECTRICAL COMPONENT DEFECTS ...
Страница 303: ......
Страница 307: ......
Страница 309: ......
Страница 497: ......
Страница 498: ...APPENDIX FAX TROUBLESHOOTING GUIDE ONLY FOR D068 D069 ...
Страница 499: ......
Страница 538: ...APPENDIX FAX SERVICE PROGRAM ONLY FOR D068 D069 ...
Страница 539: ......
Страница 645: ...PAPER TRAY UNIT B421 ...
Страница 647: ......
Страница 657: ...ARDF DF1000 B872 ...
Страница 658: ......
Страница 660: ......
Страница 662: ......