![Ricoh D067 Скачать руководство пользователя страница 265](http://html.mh-extra.com/html/ricoh/d067/d067_service-manual_1456217265.webp)
SC Tables (F/SPF: D068/D069)
D067/D068/D069/D072 3-10
SM
Appendix
No.
Definition
Symptom
Possible Cause
ADF gate abnormal 3
762 B
The ADF continues to send the
FGATE signal for more than 60
seconds after the ADF starts
scanning.
Defective
ADF
connector
Defective SBU board
Mechanical total counter error
901 B
The polling module does not detect
the mechanical total counter.
Defective mechanical total
counter
Defective
BICU
Loose
connection
Engine total counter error
903 B
The checksum of the total counter
is not correct.
Defective NVRAM on the BICU
Printer application program error
954 B
The printer application program
does not become ready when the
printer application program is
necessary.
Defective application program
Image transfer error
955 B
The BICU requests the controller to
transfer image data; but the
controller does not become ready.
Defective application program
Status error (laser optics housing unit)
964 B
The optics-housing unit does not
become ready within 17 seconds
after a request.
Defective
software
Содержание D067
Страница 1: ...D067 D068 D069 D072 SERVICE MANUAL 004356MIU ...
Страница 2: ......
Страница 3: ...D067 D068 D069 D072 SERVICE MANUAL ...
Страница 4: ......
Страница 5: ...D067 D068 D069 D072 SERVICE MANUAL 004356MIU ...
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 21: ......
Страница 23: ......
Страница 28: ......
Страница 29: ...PRODUCT INFORMATION ...
Страница 30: ......
Страница 46: ...D067 D068 D069 D072 16 SM INSTALLATION ...
Страница 88: ...Printer Scanner Unit D067 D068 D069 D072 2 42 SM ...
Страница 110: ...PREVENTIVE MAINTENANCE ...
Страница 113: ...REPLACEMENT ADJUSTMENT ...
Страница 114: ......
Страница 130: ...Fusing D067 D068 D069 D072 4 16 SM 4 5 2 EXIT SENSOR 1 Fusing unit Fusing Unit 2 Exit sensor A x 1 ...
Страница 138: ...PCU and Quenching Lamp D067 D068 D069 D072 4 24 SM 4 6 2 QUENCHING LAMP 1 PCU PCU 2 Quenching lamp A x 1 ...
Страница 183: ......
Страница 184: ...TROUBLESHOOTING ...
Страница 191: ......
Страница 222: ...DO67 D068 D069 D072 SERVICE MANUAL APPENDICES ...
Страница 223: ......
Страница 228: ...APPENDIX SPECIFICATIONS ...
Страница 229: ......
Страница 248: ...APPENDIX PREVENTIVE MAINTENANCE TABLES ...
Страница 249: ......
Страница 253: ......
Страница 254: ...APPENDIX SERVICE CALL CONDITIONS ...
Страница 255: ......
Страница 302: ...APPENDIX ELECTRICAL COMPONENT DEFECTS ...
Страница 303: ......
Страница 307: ......
Страница 309: ......
Страница 497: ......
Страница 498: ...APPENDIX FAX TROUBLESHOOTING GUIDE ONLY FOR D068 D069 ...
Страница 499: ......
Страница 538: ...APPENDIX FAX SERVICE PROGRAM ONLY FOR D068 D069 ...
Страница 539: ......
Страница 645: ...PAPER TRAY UNIT B421 ...
Страница 647: ......
Страница 657: ...ARDF DF1000 B872 ...
Страница 658: ......
Страница 660: ......
Страница 662: ......