No.
Definition
Symptom
Possible Cause
542
A
Fusing temperature warm-up error (center)
The fusing temperature rises less
than 7 degrees in 2 seconds, and
this continues 5 times
consecutively.
The fusing temperature is not
detected in 25 or 35 seconds.
• Fusing thermistor defective or out of position
• Fusing lamp open
• Power supply board defective
543
A
Fusing overheat error (center)
The fusing temperature is over
230
°
C for 1 second (detected by
the thermistor).
• Fusing thermistor defective
• Power supply board defective
544
A
Fusing overheat error (center) 2
The fusing temperature is over
250
°
C for 1 second (detected by
the fusing temperature monitor
circuit).
• Fusing thermistor defective
• Power supply board defective
545
A
Fusing lamp overheat error (center)
After the fusing temperature
reaches the target temperature, the
fusing lamp does not turn off for 12
consecutive seconds.
• Fusing thermistor defective or out of position
• Power supply board defective
546
A
Unstable fusing temperature (center)
The fusing temperature varies 50
°
C or more within 1 second, and this
occurs 2 consecutive times.
• Thermistor defective or out of position
• Power supply unit defective
547
B
Zero cross signal malfunction
Zero cross signals are not detected
within 5 seconds after the main
power switch is turned on, or are
not detected within 1 second after
operation begins.
• Power supply board defective
• BICU defective
Service Call Conditions
183
6
Содержание Aficio MP 1600L2
Страница 1: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Field Service Manual 3 December 2010 ...
Страница 2: ......
Страница 12: ...10 ...
Страница 14: ...Machine Configuration 1 Product Information 12 1 ...
Страница 20: ...1 Product Information 18 1 ...
Страница 70: ...2 Installation 68 2 ...
Страница 71: ...3 Preventive Maintenance PM Tables See Appendices for the PM Tables 69 3 ...
Страница 74: ...7 Wait until the message Completed shows 8 Quit the SP mode 3 Preventive Maintenance 72 3 ...
Страница 86: ...Platen Cover Sensor 1 Top rear cover 2 Platen cover sensor A x 1 4 Replacement and Adjustment 84 4 ...
Страница 121: ...Paper Size Switch 1 Paper cassette 2 Switch cover A x 1 3 Paper size switch B x 1 Paper Feed Section 119 4 ...
Страница 139: ...PSU Power Supply Unit 1 Left cover p 79 2 PSU A All connectors x 6 Other Replacements 137 4 ...
Страница 151: ...SP Mode Tables See Appendices for the SP Mode Tables SP Mode Tables 149 5 ...
Страница 171: ...1 1 0 0 A5 SEF 1 1 1 0 B5 SEF 1 Detected Using SP Modes 169 5 ...
Страница 207: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Appendices 3 December 2010 ...
Страница 208: ......
Страница 210: ...2 ...
Страница 228: ...2 Appendix Preventive Maintenance 20 2 ...
Страница 262: ...MEMO 54 ...
Страница 263: ...MEMO 55 ...
Страница 264: ...MEMO 56 EN ...