Technical Specifications:

Model

GTR207

Power supply

240V/50Hz

Motor power

170W

Gate moving speed

16-18m/min

Maximum weight of gate

800 Kg

Remote control distance

Up to 30m

Remote control mode

Single button mode

Limit switch

Spring limit switch

Noise

Up to 58dB

Working duty

S2, 20min (20 minutes continuous operation)

IP Rating

IP54

Maximum Remote  

Controls to be paired

25

Frequency

433.92 MHz

Working temperature

-20°C ~ +70°C

Fig 03

Содержание GTR207

Страница 1: ...nal 613 9551 2233 For installation or troubleshooting assistance visit richmondau com gate motor support When mounting and positioning the motor ensure that the power cable is unplugged The motor cove...

Страница 2: ...he gate at the push of a button Hard Wire Push Button GTR202 Allows access through the gate at the push of a button Reflective Photocells GTR208 Increase safety during opening closing by preventing ga...

Страница 3: ...6 Fitting the Mounting Plate Motor 13 Step 7 Gear Rack Motor Alignment 14 Step 8 Limit Travel Stops 16 Step 9 Powering the Motor 18 Step 10 Testing the Limit Travel Stops 19 Programming and Wiring Con...

Страница 4: ...on This will give you an understanding of the way in which the motor will move the gate If your gate needs to open from the other direction to the left refer to fig 2 your motor needs to be mounted on...

Страница 5: ...hile moving Please ensure a warning sign provided is fitted to the gate If required install infrared photocells sold separately to detect obstructions and prevent injury or damage Instruct all users a...

Страница 6: ...11 for more info 1 4 Manual release keys These keys are needed during power outage keep on hand 2 5 Remote controls factory paired to motor 2 6 Gate Warning Signage must be fitted to gate 1 7 In the...

Страница 7: ...16 18m min Maximum weight of gate 800 Kg Remote control distance Up to 30m Remote control mode Single button mode Limit switch Spring limit switch Noise Up to 58dB Working duty S2 20min 20 minutes co...

Страница 8: ...re mounted outdoors a RCD Protected Weatherproof PowerPoint will be required This will require a licensed electrician to install Any works done to the motor must be completed whilst the power is off a...

Страница 9: ...evel 12mm Masonry Drill Bit for the 4 motor masonry anchor bolts Socket and Spanner Set Phillips Head Screwdriver Example Sliding Gate Setup If you require any gate hardware contact Richmond Wheel Cas...

Страница 10: ...els and guide rollers should rotate easily and be free from dirt grime Track should be flat level and firmly affixed Any misalignment in the gate will affect performance of the automatic gate opener T...

Страница 11: ...able when installing the power supply Option 1 Run the cable across the yard property and bury it Option 2 Run the cable along the fence line of the property and secure out of the way For added protec...

Страница 12: ...ode and check that the motor cog rotates freely by hand As per Fig 23 Place the motor and motor mounting plate on the concrete pad Make sure the distance between the gate motor cog and gear rack posit...

Страница 13: ...plate ensuring the power cord is positioned into the end slot of the mounting plate in the direction of the power point making sure there are no pinch points as per fig 17 Slide rubber grommet along t...

Страница 14: ...rry any weight of the gate It is the task of the gate castors or wheels to carry the weight of the gate As per Fig 22 If the gate doesn t slide freely by hand adjust gear racks height accordingly unti...

Страница 15: ...GTR207 Installation Manual Rev 1b 15 Fig 24 At this stage of final assembly the cover is removed not shown and the power cable is still unplugged...

Страница 16: ...n setting new limit travel stop positions please ensure that you turn the power off and then on again Turning the power off will reset the limit travel stop memory allowing for new limit travel stop p...

Страница 17: ...7 Installation Manual Rev 1b 17 Fig 28 Fig 29 M6 x 10mm M6 x 10mm GTR207 Motor Gear Rack Limit Travel Stop Motor Gear Cog Spring Limit Switch Mounting Plate This diagram shows the gate in the open pos...

Страница 18: ...Part 5 included in this kit are factory paired ready for use Please Note The default setting is opening to the right Press the remote control and the gate will open until the spring limit travel stop...

Страница 19: ...osed final position for the gate frame is 10 15mm from closed gate end catch GTR019 Testing the open position Press remote The gate will begin to open The limit travel stop will hit the spring limit s...

Страница 20: ...ram 01 Ensure power is off before any modifications are made Dip Switches J10 Terminal J8 Terminal J4 Terminal J2 Terminal 24VDC BAT Terminal J7 Terminal Fuse holder J1 Terminal Learn Button Potentiom...

Страница 21: ...efore any modifications are made Learn Button Storage Battery 24VAC 24VAC Motor 24VDC Infrared Sensor COM COM COM CLOSED OPEN Stop Button Close Button Open Button Warning Lamp M Please refer to page 2...

Страница 22: ...made 30m Direct Bury Cable J2 Terminal Please note 24VAC power has no postitive or negative so either wire from the low voltage power supply can be secured in either of the positions in the J2 POWER t...

Страница 23: ...is OFF External Button Mode Leave in OFF position unless an additional module is used Default position is OFF 4 OFF Hard wire keypad Left Right Open Setting OFF Right hand open ON Left hand open Gate...

Страница 24: ...to decrease The default setting is at maximum When stall force is enabled DIP switch 7 is at the ON position the motor will detect obstacles and impacts to the gate If this is during opening the gate...

Страница 25: ...4 Terminal 2 Optional External Close Push Button Switch Terminal 3 Optional External Stop Push Button Switch Terminal 4 Common Terminal for All Optional Push Buttons J10 Terminal Limit Switch Wiring O...

Страница 26: ...Fitted pre wired Circuit board connection for low voltage power supply J4 MOT Terminal Factory Fitted pre wired DC motor wire connection Red wire to top black wire to bottom BAT Terminal Battery Backu...

Страница 27: ...will depend on the size and setup of your gate position of the panels and geographical area Under normal conditions we recommend 2 x 12V 12Ah batteries and 1 24V 30W solar panel Note that performance...

Страница 28: ...tion the gate should be checked every 6 months Check and tighten anchor bolts Check for loose and corroded wires Ensure your gate can still move smoothly by hand by placing the gate into manual mode u...

Страница 29: ...e sure photocell beams are correctly positioned Gate does not move when button is pressed but motor makes a noise 1 Gate is out of alignment 1 Connect in manual mode and check if it can be opened by h...

Страница 30: ...or assistance with installing your gate motor visit richmondau com gate motor support Or ring your local Richmond Wheel Castor Branch AU 1300 474 246 NZ 0800 61 71 81 International 613 9551 2233 Richm...

Страница 31: ...GTR207 Installation Manual Rev 1b 31 Additional Drawings and Measurements 230mm 270mm 300mm Fig 36...

Отзывы: