D Group (AC CHARGER)
D1 Group (Charger)
D1-02: Battery Charging Curve
Main Menu>Programming>ENT>Charger>ENT
Setting Function
D1-02=1 Fixed
D1-02=2 Adaptive
D1-02=3
(Initial setting)
Ad Battery safe
z
The Fixed (D1-02=1) charge curve will have a faxed Absorption Time (D1-06).
z
The Adaptive (D1-02=2) and Ad Battery safe (D1-02=3) curve derive the Absorption
time from the Bulk time. The maximum Absorption time of these charge curves is determined
by Absorption Time (D1-06) setting.
z
The Ad Battery safe (D1-02=3) curve has a special regulation in the absorption phase.
The absorption phase will start when the battery voltage reaches 14.4V( for 12V batteries)
regardless of the specified Absorption Voltage (D1-03). During the absorption phase, the
voltage will increase with a fixed ramp until the voltage reaches the absorption voltage or the
calculated absorption time is over in the latter case, the absorption phase will end before the
absorption voltage is reached.
Содержание Invertek SuperCombi SC-1500-12X
Страница 1: ......
Страница 2: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 2...
Страница 9: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 9 Layout...
Страница 125: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 125 Chapter 8 Constants list...
Страница 155: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 155 NOTES...