Rich Electric Co. “SuperCombi” User Manual V7.19 Copyright 2009
Page 56
U2-20: DC Gen Supply Voltage (Start Battery)
Main Menu>Operation>ENT>Monitor>ENT>
z
Use constant U2-20 to monitor the DC Gen input supply voltage (Start Battery)
Value in unit of 0.01V. When the current fault occurs.
U2-21: DC Gen Output Voltage
Main Menu>Operation>ENT>Monitor>ENT>
z
Use constant U2-21 to monitor the DC Gen output voltage (House Battery) value in
unit of 0.01V. when the current fault occurs.
U2-30: DC Load Status
Main Menu>Operation>ENT>Monitor>ENT>
z
Use constant U1-30 to monitor DC Load status after DC-SW module is connected to
the extension port (Port C). when the current fault occurs.
U2-33: Battery Temperature Sensor
Main Menu>Operation>ENT>Fault Trace>ENT>
z
Use constant U2-33 to monitor the current temperature that has been detected by
Battery Temperature Sensor (BTS-3) in unit of 1
℃
when the current fault occurs.