Rich Electric Co. “SuperCombi” User Manual V7.19 Copyright 2009
Page 152
The ambient temperature is
too high, or the load is
excessive.
Place the “SuperCombi®”
in a cool and well-ventilated
room, or reduce the load.
‘ ’: blink
Voltage ripple on the DC
input exceeds 1.25Vrms
Check the battery cables and
terminals.
Check the battery capacity;
increase it if necessary.
The INVERTER of
“SuperCombi®” cuts out as
a result of excessive voltage
ripple on the DC input
Install batteries with a higher
capacity.
Use shorter and/or thicker
battery cables and reset the
SuperCombi® (Power OFF
and ON again).
‘ ’: blink
Battery charger is not in
normal charging status to
cause battery voltage too
high.
Incorrect battery voltage
connection (12V system but
connected to 24V battery)
“SuperCombi®” will need to
be sent to service for repair.
Recheck if the
SuperCombi® and the
battery voltage is matched.
‘ ’: blink
The actual charge current is
1.5 times larger than the set
current value (D1-08) when
AC CHARGER is operating.
Stop the Charge mode of the
“SuperCombi®”.
“SuperCombi®” will need to
be sent to service for repair.
OH
Heatsink Max Temp.
‘Udc-ripple’
Volt Ripple Exceeds
Udc-ripple
Volt Ripple Exceeds
‘Udc-OV’
Battery over voltage.
Udc-OV
Battery over voltage.
‘Idc-OC’
Over current.
Idc-OC
Over current.
Содержание Invertek SuperCombi SC-1500-12X
Страница 1: ......
Страница 2: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 2...
Страница 9: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 9 Layout...
Страница 125: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 125 Chapter 8 Constants list...
Страница 155: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 155 NOTES...