![Rich electric Invertek SuperCombi SC-1500-12X Скачать руководство пользователя страница 111](http://html1.mh-extra.com/html/rich-electric/invertek-supercombi-sc-1500-12x/invertek-supercombi-sc-1500-12x_user-manual_1454304111.webp)
Rich Electric Co. “SuperCombi” User Manual V7.19 Copyright 2009
Page 111
H1 Group (DC Controller)
H1-01: DC Load Enable
Main Menu>Programming>ENT> DC Controller 1 >ENT
Setting Function
H1-01=1
(Initial setting)
DC Controller 1 is Enabled (active)
H1-01=0
DC Controller 1 is Disabled
H1-02: Low Voltage Disconnect
Main Menu>Programming>ENT> DC Controller 1 >ENT
z
Use constant H1-02 to adjust the DC controller disconnection voltage. When the voltage is
lower than set in constant H1-02, the DC controller will be disconnected.
H1-03: Low Voltage for ? sec
Main Menu>Programming>ENT> DC Controller 1 >ENT
z
Use constant H1-03 to determine the minimum disconnect detection time. Once the input
voltage is lower than H1-02, for longer than the time set in H1-03, the DC controller will
disconnect load to prevent the battery from being exhausted.
H1-04: Reconnection Voltage
Main Menu>Programming>ENT> DC Controller 1 >ENT
z
Use constant H1-04 to adjust the DC controller reconnection voltage. When the voltage is above
set in constant H1-04,for longer than the time set in H1-05 Sec, the DC controller will be allow
the load to connect to the battery.
Содержание Invertek SuperCombi SC-1500-12X
Страница 1: ......
Страница 2: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 2...
Страница 9: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 9 Layout...
Страница 125: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 125 Chapter 8 Constants list...
Страница 155: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 155 NOTES...