Table 4-9. DIG I/O Menu Parameters
DIG I/O Menu
Parameter
Choices
Description
Level 2 submenus
SLOT
x
BIT
y
Lists available digital I/O slots.
Level 3 submenus
BIT
y
OFF
INPUT
OUTPUT
PROGIN
ZERO
NT/GRS
TARE
UNITS
PRINT
ACCUM
SETPNT
TIMDATE
ESC
CLEAR
DSPTAR
IDKEY
KEY0—KEY9
KEYDP
ENTER
NAVUP
NAVDN
NAVLFT
NAVRGT
KBDLOC
HOLD
BATRUN
BATSTRT
BATPAUS
BATRESET
BATSTOP
CLRCN
GROSS
NET
PRIM
SEC
TER
CLRTAR
CLRACC
TRIGGER
Specifies the function of the digital I/O bit.
• OFF indicates that the bit is not configured.
• INPUT assigns the bit as a digital input used for DIGIN setpoints.
• OUTPUT assigns the bit as a digital output for setpoint or program use.
• PROGIN assigns the bit as a digital input used to generate a program event.
• ZERO, NT/GRS (net/gross mode toggle), TARE, UNITS, and PRINT provide the same
functions as the five major front panel keys.
• ACCUM adds the current scale weight to the accumulator, if the scale accumulator is
enabled.
• SETPNT, and TIMDATE provide the same functions as the Setpoint and Time/Date softkeys.
• ESC provides a function equivalent to the Cancel softkey.
• CLEAR simulates pressing the front panel CLR key.
• DSPTAR displays the current tare; equivalent to pressing the Display Tare softkey.
• IDKEY displays a prompt to enter a new unit ID; equivalent to pressing the Unit ID softkey.
• KEY0—KEY9 and KEYDP (decimal point) simulate pressing keys on the numeric keypad.
• ENTER simulates pressing the front panel ENTER key.
• NAVUP, NAVDN, NAVLFT, and NAVRGT simulate pressing the navigation keys.
• KBDLOC locks the keyboard (indicator front panel) when held low.
• HOLD holds the current display. Releasing this input clears the running average filter.
• BATRUN allows a batch routine to be started and run. With BATRUN active (low), the
BATSTRT input starts the batch; if BATRUN is inactive (high), BATSTRT resets the batch.
• BATSTRT starts or resets a batch routine, depending on the state of the BATRUN input.
• BATPAUS pauses a batch routine when held low.
• BATRESET stops the batch sequence and resets to the first batch step.
• BATSTOP stops the batch routine.
• CLRCN resets the consecutive number to the value specified on the CONSTUP parameter
(FEATURE menu).
• GROSS, NET, PRIM, SEC, and TER select gross or net weight display, and primary,
secondary, or tertiary units display modes.
• CLRTAR clears the current tare for the active scale.
• CLRACC clears the active accumulator.
• TRIGGER
Level 4 submenus
TRIGGER subparameters
OUTSLOT
NONE
PORT 3
Specifies the card slot receiving the trigger output.
PARAM
0
number
Specifies the value passed as a parameter to the option card in the specified slot.
46
CLS-920i Installation Manual
Содержание CLS-920i
Страница 2: ...96312 Rev A CLS 920i 920i Cargo Lift Scale Installation Manual...
Страница 3: ......
Страница 72: ...CLS 920i Installation Manual 68 8 1 2 Closed PRO Report The following gives an example of a closed PRO report...
Страница 73: ...69 CLS 920i Installation Manual 8 1 3 All PRO Report The following gives an exaple of an all PRO report...
Страница 76: ...CLS 920i Installation Manual 72...
Страница 77: ...73 CLS 920i Installation Manual...
Страница 78: ...CLS 920i Installation Manual 74 9 2 Scanning Refer to the following steps when scanning an item...
Страница 93: ...89 CLS 920i Installation Manual 10 9 Dimension Drawings 13 5 6 54 7 8 Figure 10 6 Panel Mount Model Dimensions...
Страница 96: ......
Страница 97: ...PN 96312 11 12...