Table 4-5. CLS-920i Serial Menu Parameters
SERIAL Menu
Parameter
Choices
Description
Level 2 submenus
PORT 1
PORT 2
PORT 3
PORT 4
…
PORT
x
CMD
PROGIN
KEYBD
SCALE
IND SC
IQUBE
Specifies the type of data received by the port:
CMD:
Remote command input
PROGIN: Programmable input
KEYBD:
Remote keyboard input
SCALE:
Legal-for-trade serial scale input
IND SC:
Industrial (non-legal-for-trade) scale input
IQUBE:
iQUBE
serial scale input
KEYBD is available only on Port 2; SCALE, IND SC, IQUBE, and HIPREC are available only on
Ports 3 and 4 and higher (expansion ports).
Note
The keyboard interface is not hot-pluggable. Power-off the
920i
before
plugging the keyboard cable into the Port 2 connector.
Level 3 Submenus
Port 1–Port 32
CONFIG
4/0/0/0
8/0/0/0
8/4/0/0
8/4/4/0
8/8/0/0
4/4/0/0
4/4/4/0
4/4/4/4
4/8/0/0
iQube board configuration
.
CELLS
CELLA1
CELLA2
CELLA3
CELLA4
iQube load cell configuration
SECTION
PAIRED
CIRCULAR
iQube section definition
PLATFRM
A1
A2
iQube platform definition
SYSTEM
PLATFRM1
iQube platform definition
ALGOUT
SOURCE
FULLSC
iQube analog output definition
DIGIO
Leave at
default setting
iQube digital I/O configuration
IQDIAG
Leave at
default setting
iQube diagnostics parameter
TESTCOM
VALIDATE
iQube communications tester
PORTTYPE
232
485
Specifies whether Port 4 is used for RS-232 or RS-485 communications. If 485 is selected,
additional prompts are shown to specify half- or full-duplex operation and RS-485 address.
Note
RS-485 communications can be specified for Port 4, and for odd numbered
expansion ports 5 and higher.
36
CLS-920i Installation Manual
Содержание CLS-920i
Страница 2: ...96312 Rev A CLS 920i 920i Cargo Lift Scale Installation Manual...
Страница 3: ......
Страница 72: ...CLS 920i Installation Manual 68 8 1 2 Closed PRO Report The following gives an example of a closed PRO report...
Страница 73: ...69 CLS 920i Installation Manual 8 1 3 All PRO Report The following gives an exaple of an all PRO report...
Страница 76: ...CLS 920i Installation Manual 72...
Страница 77: ...73 CLS 920i Installation Manual...
Страница 78: ...CLS 920i Installation Manual 74 9 2 Scanning Refer to the following steps when scanning an item...
Страница 93: ...89 CLS 920i Installation Manual 10 9 Dimension Drawings 13 5 6 54 7 8 Figure 10 6 Panel Mount Model Dimensions...
Страница 96: ......
Страница 97: ...PN 96312 11 12...