CLS-920i Installation Manual
27
DFSENS
2OUT
4OUT
8OUT
16OUT
32OUT
64OUT
128OUT
Digital filter cutout sensitivity. Specifies the number of consecutive readings that must fall
outside the filter threshold (DFTHRH parameter) before digital filtering is suspended.
See Section 10.9 on page 119 for more information about digital filtering.
DFTHRH
NONE
2D
5D
10D
20D
50D
100D
200D
250D
Digital filter cutout threshold. Specifies the filter threshold, in display divisions. When a
specified number of consecutive scale readings (DFSENS parameter) fall outside of this
threshold, digital filtering is suspended. If NONE is selected, the filter is always enabled.
See Section 10.9 on page 119 for more information about digital filtering.
RATTRAP
OFF
ON
Enables RATTLETRAP
®
digital filtering. RATTLETRAP is most effective at filtering repeating
vibrations caused by mechanical noise from nearby machines but may increase settling
times over standard digital filter selections.
SMPRAT
120HZ
240HZ
480HZ
960HZ
7.5HZ
15HZ
30HZ
60HZ
Sample rate. Selects measurement rate, in samples per second, of the analog-to-digital
converter. Lower sample rate values provide greater signal noise immunity: the default 120
Hz value may be too fast to provide the desired stability in some static weighing
applications.
NOTE: The maximum total sample rate for all configured A/D channels—the sum of the
sample rates for all scales—is 1200 Hz. For example, up to ten scales can be configured
with 120 Hz sample rates, or up to twenty scales with 60 Hz sample rates.
PWRUPMD
GO
DELAY
Power up mode. In GO mode, the indicator goes into operation immediately after a brief
power up display test.
In DELAY mode, the indicator performs a power up display test, then enters a 30-second
warm up period. If no motion is detected during the warm up period, the indicator becomes
operational when the warm up period ends; if motion is detected, the delay timer is reset
and the warm up period repeated.
TAREFN
BOTH
NOTARE
PBTARE
KEYED
Enables or disables push-button and keyed tares. Possible values are:
BOTH: Both push-button and keyed tares are enabled
NOTARE: No tare allowed (gross mode only)
PBTARE: Push-button tares enabled
KEYED: Keyed tare enabled
ACCUM
OFF
ON
Accumulator. Specifies whether the scale accumulator is enabled. If enabled, accumulation
occurs whenever a print operation is performed.
VISIBL
ON
OFF
Scale visibility. Specifies whether scale data is displayed.
CALIBR
WZERO
WVAL
WSPAN
WLIN
REZERO
See Level 4 submenu descriptions in Table 4-6 on page 32.
SCALES Menu
Parameter
Choices
Description
Table 4-2. SCALES Menu Parameters (Continued)
Содержание CLS-920i
Страница 2: ...96312 Rev A CLS 920i 920i Cargo Lift Scale Installation Manual...
Страница 3: ......
Страница 72: ...CLS 920i Installation Manual 68 8 1 2 Closed PRO Report The following gives an example of a closed PRO report...
Страница 73: ...69 CLS 920i Installation Manual 8 1 3 All PRO Report The following gives an exaple of an all PRO report...
Страница 76: ...CLS 920i Installation Manual 72...
Страница 77: ...73 CLS 920i Installation Manual...
Страница 78: ...CLS 920i Installation Manual 74 9 2 Scanning Refer to the following steps when scanning an item...
Страница 93: ...89 CLS 920i Installation Manual 10 9 Dimension Drawings 13 5 6 54 7 8 Figure 10 6 Panel Mount Model Dimensions...
Страница 96: ......
Страница 97: ...PN 96312 11 12...