background image

Introduction

1

1.0

Introduction

The 

BenchPro Series

 family of digital bench scales is ideal for many diverse industries and markets around the 

world. As a general purpose scale, the 

BenchPro

 offers many benefits, including the ability to tare containers and 

battery operation. Because of these extra features not typically found in traditional shipping, point of sale and postal 
scales, the 

BenchPro

 may be used for additional applications including retail, restaurant and deli, manufacturing, 

inventory control and more. 

Manuals can be viewed and downloaded from the Rice Lake Weighing Systems website at 

www.ricelake.com

Warranty information can be found on the website at 

www.ricelake.com/warranties

1.1

Safety

Safety Signal Definitions:

DANGER

Indicates an imminently hazardous situation that, if not avoided, will result in death or serious 
injury.  Includes hazards that are exposed when guards are removed.

WARNING

Indicates a potentially hazardous situation that, if not avoided could result in serious injury or 
death. Includes hazards that are exposed when guards are removed.

CAUTION

  Indicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury.

Important

Indicates information about procedures that, if not observed, could result in damage to 
equipment or corruption to and loss of data.

General Safety

Do not operate or work on this equipment unless this manual has been read and all 
instructions are understood. Failure to follow the instructions or heed the warnings could 
result in injury or death. Contact any Rice Lake Weighing Systems dealer for replacement 
manuals. 

WARNING

Failure to heed may result in serious injury or death.

Ensure every individual operating or working with this unit has read and understands the following safely information.

Do not allow minors (children) or inexperienced persons to operate this scale.

Prior to cleaning, make sure the scale is disconnected from the power source.

Do not use this product if any of the components are loose or cracked.

Do not use in the presence of flammable materials.

Operating at voltages and frequencies other than specified could damage the equipment. 

Do not use near water and avoid contact with excessive moisture.

Do not drop the scale or subject it to violent shocks.

Do not make alterations or modifications to the scale.

For accurate weighing, the scale must be placed on a stable, level surface.

Содержание BenchPro Series

Страница 1: ...BenchPro Series Version 1 Operation Manual PN 180557 Rev B...

Страница 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Страница 3: ...rator Display 3 1 3 3 Keys and Symbols 4 1 4 Capacity by Model Type 5 1 5 Operation 6 1 5 1 Initial Power Up 6 1 5 2 Weigh Mode 6 1 5 3 Tare 6 2 0 Setup 7 2 1 Unpacking the Scale 7 2 2 Scale Setup 7 2...

Страница 4: ...d topics at no cost Visit www ricelake com webinars 6 0 Maintenance and Troubleshooting 34 6 1 Troubleshooting 34 6 2 Load Cell Wiring 34 6 3 Replacement Parts 35 7 0 Specifications 36 Rice Lake conti...

Страница 5: ...tially hazardous situation that if not avoided could result in minor or moderate injury Important Indicates information about procedures that if not observed could result in damage to equipment or cor...

Страница 6: ...enchPro Series Options 1 2 3 Display Mounting Options Each model includes a mounting bracket The bracket attaches to the base plate or can be mounted on the wall The operator display attaches to the m...

Страница 7: ...play 14 2 361 mm 14 0 356 mm 14 5 368 mm 14 6 371 mm 2 7 69 mm 2 8 72 mm Figure 1 2 Dimensions Scale Mount Operator Display 1 3 2 Optional Column Post Mount Operator Display 14 5 368 mm 14 5 368 mm 14...

Страница 8: ...Toggle between configured weight units Enter or accept the value selected Perform a tare function if enabled Scroll left Quick press to enter the user menu and configure and parameters of the scale S...

Страница 9: ...platter Note Additional capacity labels are provided with each unit If using a scale in the applicable lb oz mode or multi range kg mode install the correct label over the existing capacity markings...

Страница 10: ...splays to indicates the scale is stable zero 1 5 3 Tare The tare function must be enabled in the configuration menu for the tare key to be functional The factory default setting is disabled 1 Place an...

Страница 11: ...Place the scale on a sturdy level surface near a power outlet Ensure the scale or weight platter are not touching any objects 3 Level the scale by adjusting the leveling feet until the bubble level u...

Страница 12: ...USB and RS 232 at the same time RS 232 USB Display Adapter Figure 2 1 BenchPro Connections 2 5 Primary Operator Display Mounting Options The primary operator display is included with each scale and c...

Страница 13: ...AM ROM DIV A DIV O Diagnostics Done exit Note After selecting all parameter settings move to the parameter and press to confirm and save settings 3 2 Service Menu The service menu provides all configu...

Страница 14: ...in non approved applications use this feature to return the scale to zero weight if in a high vibration environment Lo Med Hi Filter controls the weight display update rate used if the weight display...

Страница 15: ...easure Applicable settings are dependant on the model of scale purchased see Section 1 4 on page 5 for available selections Most models have a minimum of two units of measure turned on To avoid incorr...

Страница 16: ...tions may affect the accuracy of the BenchPro Series scale upon initial installation The scale includes a feature that allows for adjustment of the gravity setting to the location and reducing the nee...

Страница 17: ...de and altitude Please note these website address are provided for reference only and may change National Geophysical Data Center www ngdc noaa gov Measurement Canada www ic gc ca Map Coordinates www...

Страница 18: ...ce the weight platter back onto the scale is displayed 4 Press until is displayed 5 Press to accept or is displayed 6 Press to scroll to 7 Press to accept is displayed 8 Press is displayed 9 Use Table...

Страница 19: ...instructed by Rice Lake Weighing Systems and an authorized scale technician The BenchPro Series includes an optional linear calibration feature This is an additional feature to perform after a span ca...

Страница 20: ...ilize 22 Press to accept and perform Point2 calibration The calibration data is saved and the scale returns to the weigh mode The weight value displayed must match the value of the calibration weight...

Страница 21: ...ice Lake Weighing Systems website 5 2 I O Specifications The BenchPro Series includes both a straight pass through RS 232 cable and USB Cable The functional pin out is as follows DE 9 Male Host Pin Na...

Страница 22: ...gging into the USB port turn the scale on The following is displayed Table 5 3 USB Driver Install When the driver is installed using device manager the BenchPro Series will be identified as a HID comp...

Страница 23: ...W l b sp W W o z CR LF H1 H2 CR ETX Request High Resolution weight 10x Command H CR 48h 0dh over capacity invalid data LF U U CR LF H1 H2 CR ETX under capacity LF U U CR LF H1 H2 CR ETX zero point er...

Страница 24: ...e UNIT key lb kg LF U U CR LF H1 H2 CR ETX simulate UNIT key lb oz LF l b o z CR LF H1 H2 CR ETX Power off the scale Command X CR 58h 0dh simulate OFF key Unrecognized Command Command others xxh 0dh R...

Страница 25: ...id data LF U U CR LF S H1 H2 H3 CR ETX under capacity 20d LF U U CR LF S H1 H2 H3 CR ETX zero point error Initial Zero LF U U CR LF S H1 H2 H3 CR ETX in lb oz kg g normal data LF p W W W W W U U CR LF...

Страница 26: ...kg LF 2 CR ETX simulate TARE key oz LF 3 CR ETX simulate TARE key lb LF 4 CR ETX simulate TARE key lb oz LF 5 CR ETX Returns scale capabilities Command A CR 41h 0dh Response LF v w x y z CR ETX curren...

Страница 27: ...b CR ETX capacity 6 kg LF 6 k g CR ETX capacity 15 kg LF 1 5 k g CR ETX capacity 35 kg LF 3 5 k g CR ETX capacity 50 kg LF 5 0 k g CR ETX capacity 75 kg LF 7 5 k g CR ETX capacity 150 kg LF 1 5 0 k g...

Страница 28: ...ys 1 always 1 always 1 5 always 1 always 1 always 1 6 always 0 always1 always 0 7 parity parity parity 24 BenchPro Series Operation Manual 5 4 3 8213 Interface Protocol 8213 Protocol Request displayed...

Страница 29: ...W W W W W U U CR in lb oz STX W l b W W W W W o z CR in lb oz STX W W l b W W W W o z CR in lb oz STX W W W l b W W W o z CR in lb oz STX sp W W W W l b W W o z CR Request scale to zero Command Z 5ah...

Страница 30: ...Symbols Used STX start of test 02h CR carriage return 0Dh sp space 20h U U measure units lb oz kg g W W W W W weight data 5 6 Bytes Bit Definition Bit Status S 0 0 stable 1 no stable 1 0 not over cap...

Страница 31: ...W W W U U CR in lb oz kg g STX W W W W W U U CR in lb oz kg g STX sp W W W W W U U CR in lb oz STX W l b W W W W o z CR in lb oz STX W W l b W W W o z CR in lb oz STX sp W W W l b W W o z CR Request c...

Страница 32: ...eries Operation Manual 5 4 5 SMA Interface Protocol SMA Protocol Request displayed weight Command LF W CR 0Ah 57h 0dh in lb oz kg g normal data LF s r n m f W W W W W W W W W U U U CR in lb oz kg g LF...

Страница 33: ...U U U CR in lb oz kg g LF s r n m f W W W W W W W W W U U U CR in lb oz kg g LF s r n m f W W W W W W W W W U U U CR in lb oz kg g LF s r n m f W W W W W W W W W W U U U CR in lb oz LF s r n m f W W W...

Страница 34: ...W U U U CR Change units of measure Command LF U CR 0Ah 55h 0dh Response LF s r n m f W W W W W W W W W U U U CR Invoke scale diagnostics Command LF D CR 0Ah 44h 0dh Response LF r e c m CR About scale...

Страница 35: ...y Command LF S CR 0Ah 53h 0dh Response LF s r n m f W W W W W W W W W U U U CR Symbols Used LF line feed 0Ah CR carriage return 0Dh sp space 20h s Z Center of Zero O Over Capacity U Under Capacity E Z...

Страница 36: ...sp W W W W W U U CR H1 H2 ETX in lb oz LF p W l b sp W W W W o z CR H1 H2 ETX in lb oz LF p W W l b sp W W W o z CR H1 H2 ETX in lb oz LF p sp W W W l b sp W W o z CR H1 H2 ETX Initial Zero Error LF...

Страница 37: ...fer compatibility with scale manufacturer type or protocol identified prior to installing a software upgrade Note UPS Worldship provides access only to COM ports 1 4 when using RS 232 to USB converter...

Страница 38: ...yed is greater than the in Zero configuration Configuration error Invalid configuration settings Check configuration settings Overload error Too much weigh applied Perform calibration check LC mV Memo...

Страница 39: ...461C 20 kg load cell Model BP 1214 15R only 179736 AL 2461C 10 kg load cell Model BP 1214 6R only Load cell torque 120 kgf cm 5 179188 Battery housing cover 6 179190 AA Battery holder 7 179191 Primary...

Страница 40: ...n Condensing Communication RS 232 USB HID Other USB HID 1C19 0002 RS 232 Cable 10 DB 9 pin male to female straight pass through and null modem USB Cable 46 116 84 mm A B type USB cable Stainless Steel...

Страница 41: ......

Страница 42: ...I 54868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Speci...