27
DIP 12 - Controlling RAPID S, RAPID N, RAPID PARK series bars slow-down.
OFF -
Operation control with low speed limit switches connected separately (see photo
5)
FIXED ON THE SPRING HOLDING BALANCE
.
ON -
Operation control with low speed limit switches connected in parallel (see photo
6)
LIMIT SWITCHES FIXED ON THE DRIVE SHAFT.
OFF - Operation control with low speed limit switches separately connected (see photo
7).
LIMIT SWITCHES WITH CONTROL PANEL.
TECHNICAL FEATURES
- Temperature range
-10 ÷ + 55°C
- Humidity
< 95% without condensation
- Power supply voltage
230 or 120V~ ±10%
- Frequency
50/60 Hz
- Maximum card absorbtion
30mA
- Network microswitch
100ms
- Barrier open warning light maximum power
3 W (equivalent to 1 lamp of 3W
or 5 leds with 2.2 k
Ω
resistance in
series)
- Maximum power at blinker output
40W with resistive charge
- Voltage available for photocells and accessories 500mA 12Vdc
- Voltage available on the radio connector
200mA 12Vdc
RADIO TECHNICAL FEATURES
- Reception frequency
433.92MHz
- Impedance
52
Ω
- Sensitivity
>2.24µV
- Excitation time
300ms
- De-excitation time
300ms
- Codes in store
N° 60
- All the inputs must be used as clean contacts given that the power supply is generated
internally (safe voltage) in the card and it is set in a way to guarantee the use of the
double insulation and reinforced compared to parts with hazardous voltage.
- Any external circuits connected to the outputs of the control board, must be carried
out to make sure the double or reinforced insulation is used compared to parts with
hazardous voltage.
- All the inputs are run by a programmed integrated circuit which carries out an auto-test
at every start-up operation.
G
B
5
6
7
Содержание AC07063