background image

54

M12 x 1

Ø19,6

[2.12]

[0.77]

M12 x 1

Ø19,6

41,5

[1.63]

[0.77]

4

/16 

Bosch Rexroth AG   

Hydraulics

245LEN0040 - 0400; 245LE0130, 0150   RE 51421/07.11

Order example:

  Inline filter with mechanical optical maintenance indicator for 

p

nom.

 = 250 bar 

[3628 psi]

 with bypass valve, 

 

 

size 0100, with filter element 10 μm and electronic switching element M12x1 with 1 switching point for 

 

 

hydraulic fluid mineral oil HLP according to DIN 51524.

 

Filter: 

245LEN0100-H10XLA00-V5,0-M-R4 

Material no. R928030538

 

Maintenance indicator: 

WE-1SP-M12x1 

Material no. R928028409

Mating connectors according to IEC 60947-5-2 

(dimensions in mm 

[inch]

)

Mating connector for K24 4-pin, M12x1
with screw connection, cable gland Pg9.

Material no. R900031155

Mating connector for K24-3m 4-pin, M12x1
with potted-in PVC cable, 3 m long.
Line cross-section:

4 x 0.34 mm

2

Core marking:

1
2
3
4

Brown
White
Blue
Black

Material no. R900064381

for electronic switching element with round plug-in connection M12x1

For more round plug-in connections, see data sheet 08006.

Ordering code: 

Electronic switching element for maintenance indicator

Maintenance indicator

Electronic switching element 

= WE

Type of signal

 

1 switching point 

= 1SP

2 switching points, 3 LED 

= 2SP 

2 switching points, 3 LED and signal 
suppression at 30 °C 

[86 °F]

 

= 2SPSU

Connector

M12x1 = 

Round plug-in connection M12x1, 4-pin

EN 175301-803 = 

Rectangular plug-in connection, 

2-pin design A according to EN-175301-803  

WE

Material numbers of the electronic switching elements

Material no.

Type

Signal

Switching points

Connector

LED

R928028409

WE-1SP-M12x1

Changeover

1

M12x1

No

R928028410

WE-2SP-M12x1

Normally open (at 75 %) / nor-

mally closed contact (at 100 %)

2

3 pieces

R928028411

WE-2SPSU-M12x1

R928036318

WE-1SP-EN175301-803

Normally closed contact

1

EN 175301-803

No

Содержание 245LE0130

Страница 1: ...sistance of the filter elements e g in case of cold start Filter ratings of 3 m to 100 m By default equipped with mechanical optical maintenance indicator with memory function Flow optimized design du...

Страница 2: ...G1 x x R5 G1 1 4 x R6 G1 1 2 x S6 SAE 1 1 2 x SAE flange 6000 psi U3 SAE 10 x Pipe thread according to SAE J1926 U4 SAE 12 x U5 SAE 20 x U6 SAE 24 x Standard connection x Additional connection possib...

Страница 3: ...ilter Material no Replacement element 245LEN0040 H6XLA00 V5 0 M 30 6 6 R2 R928030280 U3 R928030472 R928006646 245LEN0063 H6XLA00 V5 0 M 52 11 4 R4 R928030281 U4 R928030473 R928006700 245LEN0100 H6XLA0...

Страница 4: ...Line cross section 4 x 0 34 mm2 Core marking 1 2 3 4 Brown White Blue Black Material no R900064381 for electronic switching element with round plug in connection M12x1 For more round plug in connectio...

Страница 5: ...green Circuit diagram drawn in plugged condition at temp 30 C op mode 30 C 20 C 86 F 68 F on off WE 2SPSU M12x1 WE 2SP M12x1 Switching element Connector Switching point 100 LED red Switching point 75...

Страница 6: ...leaned The dirt particles filtered out settle in the filter bowl 2 and in the filter element 3 Via port 0 the fil tered hydraulic fluid enters the hydraulic circuit The filter housing and all connecti...

Страница 7: ...Pressure differential Response pressure of the maintenance indicator bar psi 5 0 5 72 7 electrical electronic switching element Electrical connection Round plug in connection M12x1 4 pin Standard conn...

Страница 8: ...3 10 8 17 13 10 admissible pressure differential A bar psi 30 435 B bar psi 330 4785 Seal material for hydraulic fluids Mineral oil Ordering code Mineral oil HLP according to DIN 51524 M Flame resista...

Страница 9: ...Characteristic curves measured with HLP46 according to ISO 3968 H3XL A proper filter design is enabled by our computer program BRFilterSelect Oil viscosity Specific weight 0 9 kg dm3 p Q characterist...

Страница 10: ...S 142 SUS Characteristic curves measured with HLP46 according to ISO 3968 H3XL H10XL A proper filter design is enabled by our computer program BRFilterSelect Oil viscosity Specific weight 0 9 kg dm3 p...

Страница 11: ...SUS 315 SUS 142 SUS Characteristic curves measured with HLP46 according to ISO 3968 H10XL A proper filter design is enabled by our computer program BRFilterSelect Oil viscosity Specific weight 0 9 kg...

Страница 12: ...245 LE N Content in l US gal A1 A2 A3 1 A4 A5 A6 B1 2 B2 B3 B4 B5 B7 C1 Stan dard U SAE J1926 0040 0 21 0 06 200 7 87 94 3 70 120 4 72 156 6 14 25 0 98 146 5 75 92 3 62 60 2 36 25 0 98 85 3 35 55 2 17...

Страница 13: ...l optical maintenance indicator max tighten ing torque MA max 50 Nm 36 88 lb ft 2 Switching element with locking ring for electrical mainte nance indicator rotatable by 360 round plug in connection M1...

Страница 14: ...0040 0100 N0040 0100 NG0130 0150 0130 0150 NG0160 0400 N0160 0400 Seal M NBR seal V FKM seal Seal kit D 245LE Seal kit Material no D245LEN0040 0100 M R928028016 D245LE0130 0150 M R928028214 D245LEN016...

Страница 15: ...output via the switching element Only push the red pushbutton in again after the operating tem perature has been reached If it jumps out again immedi ately or if the electrical signal has not gone ou...

Страница 16: ...rding to 51448 are pressure holding equipment according to article 1 sec tion 2 1 4 of the pressure equipment directive 97 23 EC PED However on the basis of the exception in article 1 section 3 6 of t...

Отзывы: