system is armed and a zone configured as a ‘Master

Walk  Through’  zone  is  triggered,  the  zones  Entry-

Delay will start.  Any zones configured as ‘Slave Walk

Through’ will be disabled to allow free access to the

Control Panel to disarm the system before the Entry-

Delay expires an alarm occurs.

If access is gained via a zone that is not configured as

‘Master Walk Through’, the ‘Slave Walk Through’ zones

will operate as normal according to their programmed

Entry-Delay setting.

Note: A zone set as a ‘Master Walk Through’ zone

must be configured with an Entry-Delay.

Omit Zone

A zone may be temporarily omitted when the system

is armed using the Omit feature.  When the system is

next disarmed any zones set to Omit will be cancelled.

Zone Lockout

If a detector on an active zone is triggered while the

system is armed an alarm condition will occur.  After

the programmed alarm duration has expired the alarm

will  stop  and  the  system  will  automatically  reset.

Subsequent  detectors  triggered  will  again  initiate  an

alarm  condition.  If  a  single  zone  initiates  an  alarm

condition more than three times then that zone will be

‘Locked Out’ and any further alarm signals from that

zone will be ignored until the system is disarmed.

Note: The ‘Zone Lockout’ feature can be disabled

if required.

Event Log

The Control Panel incorporates a memory capable of

storing the last 50 system events.  This enables the

user  to  see  which  user  has  Armed/Disarmed  the

system  and  if  and  when  any  alarms  occurred.    The

time,  date  and  details  of  the  event  type  will  be

recorded for each system event.

Chime

Chime  is  a  low  security  facility  for  use  when  the

system  is  in  Standby  mode.    If  the  Chime  feature  is

ON,  and  a  detector  on  a  zone  that  has  its  Chime

function  enabled  is  triggered,  the  internal  sounder

will  produce  a  low  volume  warning  tone.    A  typical

use  of  the  Chime  function  would  be  to  warn  that  a

door or particular area has been accessed.

Voice Dialler

If the Voice Dialler is enabled and an alarm condition

occurs, the system will call for help using your recorded

alarm messages and up to four telephone numbers.

When an alarm condition occurs, the telephone voice

dialler (if enabled) will call the first enabled number in

the  calling  sequence  and  replay  the  recorded  alarm

messages for the configured ‘Play Time’.  The recipient

must  acknowledge  the  message  by  pressing  the 

button on their telephone keypad.  If the call is

unanswered  or  an  acknowledgment  is  not  received

then the next active number in the dialing sequence

will  be  called.    The  dialler  will  continue  calling  each

number in turn until either all numbers in the sequence

have  been  dialed  the  set  number  of  times  or  the

sequence is cancelled/acknowledged by the recipient.

Digital Dialler

As an alternative to the Voice dialler the system may be

configured to interface with a central monitoring station.

Latch Key

When  the  system  is  disarmed  the  Latch-Key 

facility,  if  enabled,  will  call  the  first  latchkey  phone

number  and  replay  the  user  message  (recorded 

under user setup) for the set ‘Play Time’.  The recipient

must  acknowledge  the  message  by  pressing  the

button  on  the  telephone  keypad.    If  the  call  is

unanswered or  an  acknowledgment  is  not  received

then the second latchkey phone number will be called.

The voice dialler will continue calling each number in

turn until each number has been dialed the set number

of times or the sequence is cancelled/acknowledged

by the recipient.

For  example,  the  latchkey  facility  is  useful  to  inform

parents  that  a  child  has  returned  from  school  and

disarmed the system.

Answerphone

The Control Panel includes an answer-phone facility.

The  answerphone  will  record  and  store  a  maximum

of 6 messages with each message being limited to a

30 seconds duration.

Messages  may  be  retrieved  either  direct  from  the

Control Panel or by dialing into the system from a phone.

5

Содержание SA5 E

Страница 1: ...SA5 E 36 Zone Wirefree Alarm System with Voice Dialler Installation and Operating Instructions 1 2 3 4 5 6 8 7 0 9 ESC POWER ALARM STATUS ALARM MEMORY TEL MESSAGE LINE STATUS...

Страница 2: ...etectors 14 Testing the Magnetic Contact Detectors 15 External Solar Siren 15 Positioning the Solar Siren 16 Installing the Solar Siren 16 Setting the Solar Siren 16 Initial Power Up of the Solar Sire...

Страница 3: ...and External Solar Siren x 2 9V PP3 Alkaline battery for PIR Movement Detectors x 5 3V CR2032 Lithium cells for Remote Control and Magnetic Contact Detectors Important Please check all items listed a...

Страница 4: ...zone is triggered an entry will be recorded in the Event Log but an alarm will not occur In addition there is the facility to connect 4 hard wired zones to the Control Panel each of which is fully co...

Страница 5: ...of the Chime function would be to warn that a door or particular area has been accessed Voice Dialler If the Voice Dialler is enabled and an alarm condition occurs the system will call for help using...

Страница 6: ...Solar Siren operate independently The Jamming Detection circuit is designed to permanently scan for jamming signals However it is possible that it may detect other local radio interference operating...

Страница 7: ...ments and plan your installation The alarm system may be extended at any time to provide even greater protection by fitting additional devices to meet your personal security needs Planning and Extendi...

Страница 8: ...thin reach of a mains socket 6 If the telephone voice dialler is to be used then the Control Panel will need connecting to a convenient telephone point Note It is recommended that the telephone connec...

Страница 9: ...the batteries as connecting incorrectly could damage the batteries or the Control Panel Note The Power LED may flash to indicate that the unit is being operated from the back up batteries and that ma...

Страница 10: ...urn as each button is pressed the Control Panel will beep and show the button being pressed on the display 4 Test the range of the Remote Control by pressing the DISARM button on the Remote Control fr...

Страница 11: ...mounted within effective radio range of the Control Panel The PIR Detector is powered by a PP3 Alkaline battery which under normal conditions will have an expected life in excess of 1 year When the b...

Страница 12: ...the rear cover and then slide down to release the top clips 2 Carefully drill out the required mounting holes in the rear cover using a 3mm drill according to whether the unit is being mounted in a co...

Страница 13: ...up or down ensuring that the location legs are aligned with the required position number marked on the board 11 Refit the PIR Detector to the rear cover by offering the PIR Detector up to the rear cov...

Страница 14: ...r the double sided adhesive tape or screws provided When fixing the Magnetic Contact Detector with screws the top of the Detector is secured with a keyhole slot over the screw head of the smaller pan...

Страница 15: ...for will be displayed Note In normal mode with the battery cover fitted the LED on the detector will not illuminate when the detector is triggered unless the battery is low 4 If connected operate the...

Страница 16: ...ternal or internal metalwork i e drainpipes gutters radiators mirrors etc Ensure that the position selected for the Solar Siren is within effective range of the Control Panel refer to Testing the Cont...

Страница 17: ...le to disable the beeps if required by removing the jumper link P2 on the circuit board Siren Disable If for any reason you need to disable the Siren remove jumper link P3 on the circuit board This wi...

Страница 18: ...power jack and disconnect one of the back up batteries Hardwired zone and tamper switches should be Volt free and Normally Closed with the contacts opening in order to initiate an alarm Note Jumper l...

Страница 19: ...5 seconds Select Wirefree Siren Test to operate the External Solar Siren Select Hardwired Siren Test to operate the Control Panel Siren and external hardwired Siren if connected Select Relay Test to...

Страница 20: ...sage Play Time 70 seconds Alarm Messages Not programmed Call Routing All numbers disabled Call Confirms 1 Call Attempts 3 Full Arm Setup Exit Delay ON 30 seconds Entry Delay Beep ON Exit Delay Beep ON...

Страница 21: ...leads and replace the back up battery in position Reconnect the PSU Adapter plug to the DC power socket in the Control Panel and switch On the supply to the PSU Adaptor 7 As the Control Panel powers...

Страница 22: ...to record a short 4 second message for use with the Latch Key facility e g system disarmed by User 1 Scroll through the menu until 2 Record User Message is displayed To record a new message press Pres...

Страница 23: ...ress Enter the required alarm duration in units of 10s e g enter 6 for a 60s alarm duration max setting 60 i e 600s 10mins Press to save and exit or Press to exit without saving Press to return to top...

Страница 24: ...If this is set to ON Until Disarm then the relay will latch and remain On until the system is next disarmed Default setting ON Until Disarm Scroll through the menu until 2 6 Alarm Relay is displayed T...

Страница 25: ...within the UK are now operating on a Tone DTMF based exchange Default setting Tone DTMF Scroll through the menu until 2 11 Dial Method is displayed The current setting will also be displayed To change...

Страница 26: ...andard intruder monitoring with normal ARM and PART ARM functions 24 Hour Intruder used to provide 24 hour monitoring of areas requiring continuous security protection even while the system is Disarme...

Страница 27: ...cility is available on the zone Default setting OFF Scroll through the menu until 3 4 Z01 Chime is displayed The current setting will also be displayed To change the setting press Press to enable the...

Страница 28: ...s armed Default setting OFF Scroll through the menu until 3 7 Z01 Part Arm 2 is displayed The current setting will also be displayed To change the setting press Press to enable the Zone in Part Arm 2...

Страница 29: ...out changing Note After recording the message press to stop the recorder and cancel any remaining message time Press to return to the top level Voice Dialler setup menu Replay Alarm Messages Scroll th...

Страница 30: ...croll through the menu until 5 1 EXIT DELAY is displayed The current settings will also be displayed To change the settings press On Off Status Default setting ON Scroll through the menu until 5 1 1 S...

Страница 31: ...displayed The current settings will also be displayed To change the settings press Enter the required delay period 10 to 250s Press to save and exit or Press to exit without saving Press to return to...

Страница 32: ...s displayed The current setting will also be displayed To change the setting press Press to enable the entry delay beep or Press to disable the entry delay beep Exit Delay Beep This controls the warni...

Страница 33: ...red is displayed The current status will also be displayed To change the setting press Press to enable the Latch Key for the user or Press to disable the Latch Key for the user After configuring all U...

Страница 34: ...menu until 12 REMOTE MANAGER SETUP is displayed and press Note After completing the Remote Manager setup press to return to the top level programming menu Telephone Number Scroll through the menu unti...

Страница 35: ...creasing in steps as the delay expires If the system has not been disarmed when the Entry Delay expires an alarm will occur If however the Entry Delay for the triggered zone has been disabled an alarm...

Страница 36: ...the event of threat or danger by activating a Panic Button on either the Remote Control or the Control Panel Remote Control Slide the Panic Button on the side of the Remote Control upwards Control Pa...

Страница 37: ...deleting the message just heard To delete the message Press to delete the message Press to re confirm and actually delete the message Note Press at either stage to cancel delete and move on to the ne...

Страница 38: ...attery indication will be activated In addition if any PIR or Magnetic Contact Detector has a low battery status it will be indicated on the LOW BAT LED on the Control Panel LED Glowing Magnetic Conta...

Страница 39: ...iods Detectors And Remote Control The Detectors require very little maintenance The batteries should be replaced once a year or when a low battery status is indicated IMPORTANT Should you for any reas...

Страница 40: ...Phone Numbers Phone No 1 Phone No 2 Remote Security Manager Service Phone No System ID No This information is confidential and should be kept in a safe location 40 Alarm Record Complete the following...

Страница 41: ...ted or faulty check phone line with another phone 2 Dial Method incorrectly programmed 3 Answer Phone disabled 4 No space in message store 6 messages already recorded Cannot record Voice Memo message...

Страница 42: ...the detector is not in a draughty area 5 Pulse count set too low reset to two pulse detection PIR Movement Detector not detecting a person s movement 1 Check battery connections are good 2 Pulse coun...

Страница 43: ...your statutory rights and is valid for UK and EIRE only If you believe the product to be faulty or in the unlikely event of the product developing a fault during the warranty period then please contac...

Страница 44: ...Piezo Siren 3 minute alarm duration limiter optional Auto reset Siren Disable selectable Dual front and rear anti tamper protection Jamming Detection Audible confirmation Passive Infra Red Movement De...