background image

43

Extending your Alarm System

Your system may be extended to provide additional protection by adding further PIR Movement Detectors, Magnetic

Contact Detectors and Remote Control Units.

Accessories

433MHz 

Wirefree Passive Infra-Red 

Movement Detector

SAP E

433MHz 

Wirefree Magnetic

Contact Detector

SAM E

433MHz 

Wirefree Remote

Control

SAR E

0

1

2

3

4

5

6

7

8

9

2

1

433MHz 

Wirefree Remote Keypad

SAKP E

Guarantee

The  product  is  guaranteed  for  one  year  from  the  date  of  purchase  against  faulty  materials  and

workmanship.    No  liability  can  be  accepted  for  any  problems  caused  by  fair  wear  and  tear,  buyer’s

negligence,  improper  fitting  or  use,  wilful  or  accidental  damage,  or  any  consequential  loss  or  damage

howsoever caused.  This guarantee does not affect your statutory rights and is valid for UK and EIRE only.

If you believe the product to be faulty or in the unlikely event of the product developing a fault during the

warranty period, then please contact our Customer Support Team on 0845 373 1353 for product assistance.

Product repair or replacement will be offered for faulty products only with our prior agreement.  Should you

need to return a products then:

1. Contact the Help Line on the number above to obtain a Return Authorisation Number.

2. Adequately package your product to prevent damage in transit and include the following:

a.  A copy of your original invoice/receipt.

b.  A covering letter giving your full contact details, including email address (if applicable).

c.  A description of the fault or problem.

Research and Development

Our R & D Department is constantly developing new products.  We practice a policy of continued

improvement and reserve the right to change specifications without prior notice.

Содержание SA5 E

Страница 1: ...SA5 E 36 Zone Wirefree Alarm System with Voice Dialler Installation and Operating Instructions 1 2 3 4 5 6 8 7 0 9 ESC POWER ALARM STATUS ALARM MEMORY TEL MESSAGE LINE STATUS...

Страница 2: ...etectors 14 Testing the Magnetic Contact Detectors 15 External Solar Siren 15 Positioning the Solar Siren 16 Installing the Solar Siren 16 Setting the Solar Siren 16 Initial Power Up of the Solar Sire...

Страница 3: ...and External Solar Siren x 2 9V PP3 Alkaline battery for PIR Movement Detectors x 5 3V CR2032 Lithium cells for Remote Control and Magnetic Contact Detectors Important Please check all items listed a...

Страница 4: ...zone is triggered an entry will be recorded in the Event Log but an alarm will not occur In addition there is the facility to connect 4 hard wired zones to the Control Panel each of which is fully co...

Страница 5: ...of the Chime function would be to warn that a door or particular area has been accessed Voice Dialler If the Voice Dialler is enabled and an alarm condition occurs the system will call for help using...

Страница 6: ...Solar Siren operate independently The Jamming Detection circuit is designed to permanently scan for jamming signals However it is possible that it may detect other local radio interference operating...

Страница 7: ...ments and plan your installation The alarm system may be extended at any time to provide even greater protection by fitting additional devices to meet your personal security needs Planning and Extendi...

Страница 8: ...thin reach of a mains socket 6 If the telephone voice dialler is to be used then the Control Panel will need connecting to a convenient telephone point Note It is recommended that the telephone connec...

Страница 9: ...the batteries as connecting incorrectly could damage the batteries or the Control Panel Note The Power LED may flash to indicate that the unit is being operated from the back up batteries and that ma...

Страница 10: ...urn as each button is pressed the Control Panel will beep and show the button being pressed on the display 4 Test the range of the Remote Control by pressing the DISARM button on the Remote Control fr...

Страница 11: ...mounted within effective radio range of the Control Panel The PIR Detector is powered by a PP3 Alkaline battery which under normal conditions will have an expected life in excess of 1 year When the b...

Страница 12: ...the rear cover and then slide down to release the top clips 2 Carefully drill out the required mounting holes in the rear cover using a 3mm drill according to whether the unit is being mounted in a co...

Страница 13: ...up or down ensuring that the location legs are aligned with the required position number marked on the board 11 Refit the PIR Detector to the rear cover by offering the PIR Detector up to the rear cov...

Страница 14: ...r the double sided adhesive tape or screws provided When fixing the Magnetic Contact Detector with screws the top of the Detector is secured with a keyhole slot over the screw head of the smaller pan...

Страница 15: ...for will be displayed Note In normal mode with the battery cover fitted the LED on the detector will not illuminate when the detector is triggered unless the battery is low 4 If connected operate the...

Страница 16: ...ternal or internal metalwork i e drainpipes gutters radiators mirrors etc Ensure that the position selected for the Solar Siren is within effective range of the Control Panel refer to Testing the Cont...

Страница 17: ...le to disable the beeps if required by removing the jumper link P2 on the circuit board Siren Disable If for any reason you need to disable the Siren remove jumper link P3 on the circuit board This wi...

Страница 18: ...power jack and disconnect one of the back up batteries Hardwired zone and tamper switches should be Volt free and Normally Closed with the contacts opening in order to initiate an alarm Note Jumper l...

Страница 19: ...5 seconds Select Wirefree Siren Test to operate the External Solar Siren Select Hardwired Siren Test to operate the Control Panel Siren and external hardwired Siren if connected Select Relay Test to...

Страница 20: ...sage Play Time 70 seconds Alarm Messages Not programmed Call Routing All numbers disabled Call Confirms 1 Call Attempts 3 Full Arm Setup Exit Delay ON 30 seconds Entry Delay Beep ON Exit Delay Beep ON...

Страница 21: ...leads and replace the back up battery in position Reconnect the PSU Adapter plug to the DC power socket in the Control Panel and switch On the supply to the PSU Adaptor 7 As the Control Panel powers...

Страница 22: ...to record a short 4 second message for use with the Latch Key facility e g system disarmed by User 1 Scroll through the menu until 2 Record User Message is displayed To record a new message press Pres...

Страница 23: ...ress Enter the required alarm duration in units of 10s e g enter 6 for a 60s alarm duration max setting 60 i e 600s 10mins Press to save and exit or Press to exit without saving Press to return to top...

Страница 24: ...If this is set to ON Until Disarm then the relay will latch and remain On until the system is next disarmed Default setting ON Until Disarm Scroll through the menu until 2 6 Alarm Relay is displayed T...

Страница 25: ...within the UK are now operating on a Tone DTMF based exchange Default setting Tone DTMF Scroll through the menu until 2 11 Dial Method is displayed The current setting will also be displayed To change...

Страница 26: ...andard intruder monitoring with normal ARM and PART ARM functions 24 Hour Intruder used to provide 24 hour monitoring of areas requiring continuous security protection even while the system is Disarme...

Страница 27: ...cility is available on the zone Default setting OFF Scroll through the menu until 3 4 Z01 Chime is displayed The current setting will also be displayed To change the setting press Press to enable the...

Страница 28: ...s armed Default setting OFF Scroll through the menu until 3 7 Z01 Part Arm 2 is displayed The current setting will also be displayed To change the setting press Press to enable the Zone in Part Arm 2...

Страница 29: ...out changing Note After recording the message press to stop the recorder and cancel any remaining message time Press to return to the top level Voice Dialler setup menu Replay Alarm Messages Scroll th...

Страница 30: ...croll through the menu until 5 1 EXIT DELAY is displayed The current settings will also be displayed To change the settings press On Off Status Default setting ON Scroll through the menu until 5 1 1 S...

Страница 31: ...displayed The current settings will also be displayed To change the settings press Enter the required delay period 10 to 250s Press to save and exit or Press to exit without saving Press to return to...

Страница 32: ...s displayed The current setting will also be displayed To change the setting press Press to enable the entry delay beep or Press to disable the entry delay beep Exit Delay Beep This controls the warni...

Страница 33: ...red is displayed The current status will also be displayed To change the setting press Press to enable the Latch Key for the user or Press to disable the Latch Key for the user After configuring all U...

Страница 34: ...menu until 12 REMOTE MANAGER SETUP is displayed and press Note After completing the Remote Manager setup press to return to the top level programming menu Telephone Number Scroll through the menu unti...

Страница 35: ...creasing in steps as the delay expires If the system has not been disarmed when the Entry Delay expires an alarm will occur If however the Entry Delay for the triggered zone has been disabled an alarm...

Страница 36: ...the event of threat or danger by activating a Panic Button on either the Remote Control or the Control Panel Remote Control Slide the Panic Button on the side of the Remote Control upwards Control Pa...

Страница 37: ...deleting the message just heard To delete the message Press to delete the message Press to re confirm and actually delete the message Note Press at either stage to cancel delete and move on to the ne...

Страница 38: ...attery indication will be activated In addition if any PIR or Magnetic Contact Detector has a low battery status it will be indicated on the LOW BAT LED on the Control Panel LED Glowing Magnetic Conta...

Страница 39: ...iods Detectors And Remote Control The Detectors require very little maintenance The batteries should be replaced once a year or when a low battery status is indicated IMPORTANT Should you for any reas...

Страница 40: ...Phone Numbers Phone No 1 Phone No 2 Remote Security Manager Service Phone No System ID No This information is confidential and should be kept in a safe location 40 Alarm Record Complete the following...

Страница 41: ...ted or faulty check phone line with another phone 2 Dial Method incorrectly programmed 3 Answer Phone disabled 4 No space in message store 6 messages already recorded Cannot record Voice Memo message...

Страница 42: ...the detector is not in a draughty area 5 Pulse count set too low reset to two pulse detection PIR Movement Detector not detecting a person s movement 1 Check battery connections are good 2 Pulse coun...

Страница 43: ...your statutory rights and is valid for UK and EIRE only If you believe the product to be faulty or in the unlikely event of the product developing a fault during the warranty period then please contac...

Страница 44: ...Piezo Siren 3 minute alarm duration limiter optional Auto reset Siren Disable selectable Dual front and rear anti tamper protection Jamming Detection Audible confirmation Passive Infra Red Movement De...

Отзывы: