SA3 E PLUS  Ed.2

Control Panel

 RF operating frequency: 433MHz

 Range: Up to 100 metres

 Battery Back-up

 Detector Battery Status Indication

 6 Zones

 Part-Arm Facility

 Instant or Delayed Alarm Zones

 Entry/Exit Delay alarm mode

 Entry/Exit Delay Warning (selectable)

 90dB High Power Piezo Siren

 Connections for Hardwired Siren 

   and Auto Dialler

 Programmable 4 digit User Access Code

 Programmable Alarm Duration

 Programmable Entry/Exit Delay

 Auto Reset

 Zone Lockout

 Siren Disable (selectable)

 Dual front and rear anti-tamper

 Personal Attack (PA)

 Jamming Detection

 Low Battery Indicator

Remote Control

 RF operating frequency: 433MHz

 Range: Up to 100 metres

 Personal Attack (PA) switch

 Operates all ARM, PART-ARM and 

   DISARM functions

 Transmission indicator

 Typical Battery life > 1 year

 Low battery indicator

External Solar Siren

 RF operating frequency: 433MHz

 Sealed lead acid battery 6V/1.2Ahr

 Solar Panel 7.5V - Charge Rate 

   typically 60mA

 Operation time in complete darkness 

   – up to 25 days

 95dB Piezo Siren

 3 minute alarm duration limiter (optional)

 Auto reset

 Siren Disable (selectable)

 Dual front and rear anti-tamper 

   protection

 Jamming Detection

 Audible confirmation

Passive Infra-Red

Movement Detector

 RF operating frequency: 433MHz

 Range: Up to 100 metres

 Detection range: up to 12m at 110° 

 Walk test facility

 High/Low movement sensitivity settings

 Anti-Tamper protected

 Corner or surface mount

 Typical Battery Life > 1 year

 Low Battery Indicator

Magnetic Contact

Detector

 RF operating frequency: 433MHz

 Range: Up to 100 metres

 Test Mode

 Anti-Tamper protection

 Facility to add external wired Magnetic 

   Contact Detector or Personal Attack

buttons

 Typical Battery Life >1 year

 Low Battery Indicator 

Wirefree Remote

Keypad

(optional accessory)

 RF operating frequency: 433MHz

 Range: Up to 100 metres

 Changeable 4 digit User Access code.

 Anti-Tamper protected

 Personal Attack (PA) facility

 Typical Battery Life > 1 year

 Low Battery Indicator

225

mm

85

mm

315

mm

1

2

3

4

5

6

FIRE

TAMPER

ZONE

1

2

3

4

5

6

8

7

0

ESC

9

230

mm

52

mm

185

mm

112

mm

71

mm

45

mm

39

mm

75

mm

15

mm

125

mm

54

mm

11

mm

14

mm

26

mm

15

mm

114

mm

39

mm

85

mm

0

1

2

3

4

5

6

7

8

9

2

1

Component Specification

Note: 

Product images are for illustration purposes only.  Actual design/appearance 

may vary however the Technical Specification will be as stated.

Содержание SA3 E PLUS

Страница 1: ...SA3 E PLUS 6 Zone Wirefree Alarm System with Voice Dialler Installation and Operating Instructions...

Страница 2: ...the System 17 Initial Testing 17 Testing an Installed System 17 Detector Test 17 Hard Wired Solar Siren Test 18 Testing the System continued Solar Siren Test 18 Control Panel LED Test 18 Solar Siren...

Страница 3: ...battery for PIR Movement Detectors x 5 3V CR2032 Lithium cells for Remote Control and Magnetic Contact Detectors Important Please check all items listed above are included in the package For system i...

Страница 4: ...Delay Armed zones will not become fully armed until after the Exit delay period has expired When a Detector on a Delay Armed zone is triggered an alarm condition will not be triggered until after the...

Страница 5: ...e planning to operate the Jamming Detection feature we recommend that you wait at least 30 days before activating this feature this will allow time for you to become familiar with the operation of you...

Страница 6: ...curity requirements and plan your installation The alarm system may be extended at any time to provide even greater protection by fitting additional devices to meet your personal security needs Planni...

Страница 7: ...cted by a PIR Detector when the system is armed 5 The Control Panel must be located within reach of a mains socket 6 If the telephone voice dialler is to be used then the Control Panel will need conne...

Страница 8: ...attery terminal Blue lead to battery terminal Battery 2 right Blue lead to battery terminal Black lead to battery terminal Important Take care when connecting battery leads to the batteries as connect...

Страница 9: ...etting The LEDs will switch to the opposite state each time the button is pressed LED ON 1 House Code DIP Switch On LED OFF 0 House Code DIP Switch Off b Press to save the new setting and return to pr...

Страница 10: ...vision If movement is detected an alarm signal will be generated if the system and alarm zone is armed Note PIR Detectors will also detect animals so ensure that pets are not permitted access to areas...

Страница 11: ...range of the Device Installing and configuring the PIR Movement Detectors Ensure that the Control Panel is in Test mode 1 Undo and remove the fixing screw from the bottom edge of the PIR Detector Care...

Страница 12: ...ver Push the lower edge of the PIR Detector into place and refit the fixing screw in the bottom edge of the PIR Detector to secure in position Do not over tighten the fixing screws as this may damage...

Страница 13: ...If an additional wired Magnetic Contact Detector is required this should be wired to the terminal block provided in the battery compartment The wired contact should be connected using two core 24AWG...

Страница 14: ...ing provides full protection against adverse weather conditions An LED Strobe unit is built into the siren to act as a visible deterrent indication that the system is active The Strobe LEDs will slowl...

Страница 15: ...6mm holes and fit the wall plugs 3 Fit the two 30mm fixing screws in the top holes leaving approx 10mm of the screw protruding 4 Fit the top keyhole slots of the mounting plate over the screw heads A...

Страница 16: ...e rechargeable battery to the charging leads Connect the Red lead to the Red terminal and the Black lead to the Black terminals Note Once the batteries have been connected the Siren will be operationa...

Страница 17: ...device is tested in turn as it is installed refer to testing instructions for particular device Testing an Installed System The Control Panel has a programmed test routine You may test the system at a...

Страница 18: ...lled Press to exit voice dialer test Factory Defaults Reset Factory Default Conditions 1 Press to place the system in Test Mode 2 Undo the Control Panel cover fixing screws and open the cover 3 Switch...

Страница 19: ...D OFF House Code DIP Switch Off Press to save the new setting and return to programming Press to return to programming mode without saving b Using a Remote Control With the required House Code already...

Страница 20: ...imit of the external Siren expires whichever occurs first Part Arm Default setting Zone 1 Disabled Zones 2 6 Active Press The zone LEDs corresponding to the zones currently active during Part Arm mode...

Страница 21: ...ll illuminate 0 2 seconds 1 30 seconds 2 1 minute 3 3 minutes 4 5 minutes 5 equal to Alarm Duration Press the key corresponding to the required Hardwired output activation period the corresponding zon...

Страница 22: ...e in the number when dialed Press to save the new number and return to programming mode Press to return to programming mode without saving Alarm Message Play Time This is the total time for which the...

Страница 23: ...he phone number The LED will toggle between states each time the button is pressed Press to save the new number and return to programming mode Press to return to programming mode without saving Call A...

Страница 24: ...pires If the system has not been Disarmed when the Entry Delay expires a Full Alarm condition will be initiated If a Full Alarm condition occurs the appropriate zone LED that triggered the alarm will...

Страница 25: ...ll be initiated even if the system is disarmed The alarm condition will continue either for the alarm duration when the system will automatically reset or until the system is Disarmed from the Remote...

Страница 26: ...s covered with a light proof material to prevent it being energized Control Panel The rechargeable batteries have a typical life of 3 4 years and need no maintenance during this period provided they a...

Страница 27: ...o your system and to assist Trouble Shooting Zone Settings You may make a note of your User Access Code and System House Code below User Access Code System House Code Use the above diagram to record y...

Страница 28: ...the House Code is correctly set 2 Ensure Detector is within effective radio range of the Control Panel and equipment is not mounted close to metal objects 3 Detector battery low Replace Detector batte...

Страница 29: ...ted a Ensure jumper link removed b Check that additional contact is correctly wired c Ensure that Magnet is correctly positioned in relation to Detector and that the gap between Magnet and Detector is...

Страница 30: ...your statutory rights and is valid for UK and EIRE only If you believe the product to be faulty or in the unlikely event of the product developing a fault during the warranty period then please contac...

Страница 31: ...Notes 31...

Страница 32: ...peration time in complete darkness up to 25 days 95dB Piezo Siren 3 minute alarm duration limiter optional Auto reset Siren Disable selectable Dual front and rear anti tamper protection Jamming Detect...

Отзывы: