background image

Connect the BT plug on the other end of the lead

to an appropriate telephone outlet.

If the cable supplied is not long enough to reach a

suitable  phone  point  then  it  will  need  extending

using a coupler and extension lead (not supplied).

Note: If  the  Panel  Tamper  alarm  sounds  during  the

installation reset the alarm by pressing:

on the Control Panel Keypad.

Setting the Control Panel 
House Code

With  the  unit  in  Standby  mode  (Power  LED  only

illuminated).

1.

Press 

The Control Panel will beep twice and the Arm and

Part-Arm LEDs will illuminate.  All Zone, Fire and

Tamper LEDS will flash.

This puts the Control Panel into programming mode.

2.

Press 

The  Zone  LEDs  1-6,  Fire  and  Tamper  LEDs  will

illuminate  to  indicate  the  current  House  Code

setting with an illuminated LED indicating a setting

of  ‘ON’  and  LEDs  not  illuminated  indicating  a

setting  of  ‘OFF’.    For  example,  a  house  code  of

‘ON’,  ‘ON’,  ‘ON’,  ‘ON’,  ‘OFF’,  ‘OFF’,  ‘ON’,  ‘OFF’,

will  be  indicated  with  zone  LEDs  1 - 4  illuminated,

Zones 5 & 6 ‘not illuminated’, Fire Zone ‘illuminated’

and Tamper Zone ‘not illuminated’.

3.

The system House Code can be set either directly

at the Control Panel or via a Remote Control Unit.

At the Control Panel:

a) By  pressing  buttons  1-8  on  the  Control  Panel,

setting  the  status  LEDs  so  that  they  indicate 

the required house code setting.  The LEDs will

switch  to  the  opposite  state  each  time  the

button is pressed.

LED ON    =  1,  (House Code DIP Switch On)

LED OFF  =  0, (House Code DIP Switch Off)

b) Press               to save the new setting and return

to programming mode.

b) Press            to return to programming mode

without saving.

Using a Remote Control Unit:

a) With the required House Code already set on

the remote control, press the               button on

the Remote Control.

The  Control  Panel  will  beep  twice  to

acknowledge the signal.

The  Zone,  Fire  and  Tamper  LED  status  will

be  updated  to  correspond  with  the  House 

Code  set  on  the  Remote  Control  and  now

programmed into the Control Panel.

b) Press                to return to programming mode.

4.

Press                  to  exit  programming  mode  and

return to Standby

5.

Press 

The  Control  Panel  will  beep  and  the  Arm  and

Part-Arm LEDs will flash.

This puts the Control Panel into test mode.

Remote Control Unit

The Remote Control Unit is used to Arm, Part-Arm and

Disarm the system.

The  Remote  Control  Unit  also  incorporates  a  Panic

switch.  Activating the Panic switch on the side of the

Remote  Control  will  immediately  initiate  a  Full  Alarm

condition  whether  the  system  is  Armed  or  Disarmed.

The alarm can be cancelled by pressing the ‘DISARM’

button on the Remote Control or via the Control Panel.

Any number of Remote Control Units can be used with

your  system,  providing  they  are  all  coded  with  the

same system House Code.

9

1

2

3

4

,

,

Slide up
to operate

Transmit LED

Personal Attack

Disarm

Arm

Part-Arm

1

2

3

4

,

,

1

2

3

4

,

,

2

ESC

ESC

Содержание SA3 E PLUS

Страница 1: ...SA3 E PLUS 6 Zone Wirefree Alarm System with Voice Dialler Installation and Operating Instructions...

Страница 2: ...the System 17 Initial Testing 17 Testing an Installed System 17 Detector Test 17 Hard Wired Solar Siren Test 18 Testing the System continued Solar Siren Test 18 Control Panel LED Test 18 Solar Siren...

Страница 3: ...battery for PIR Movement Detectors x 5 3V CR2032 Lithium cells for Remote Control and Magnetic Contact Detectors Important Please check all items listed above are included in the package For system i...

Страница 4: ...Delay Armed zones will not become fully armed until after the Exit delay period has expired When a Detector on a Delay Armed zone is triggered an alarm condition will not be triggered until after the...

Страница 5: ...e planning to operate the Jamming Detection feature we recommend that you wait at least 30 days before activating this feature this will allow time for you to become familiar with the operation of you...

Страница 6: ...curity requirements and plan your installation The alarm system may be extended at any time to provide even greater protection by fitting additional devices to meet your personal security needs Planni...

Страница 7: ...cted by a PIR Detector when the system is armed 5 The Control Panel must be located within reach of a mains socket 6 If the telephone voice dialler is to be used then the Control Panel will need conne...

Страница 8: ...attery terminal Blue lead to battery terminal Battery 2 right Blue lead to battery terminal Black lead to battery terminal Important Take care when connecting battery leads to the batteries as connect...

Страница 9: ...etting The LEDs will switch to the opposite state each time the button is pressed LED ON 1 House Code DIP Switch On LED OFF 0 House Code DIP Switch Off b Press to save the new setting and return to pr...

Страница 10: ...vision If movement is detected an alarm signal will be generated if the system and alarm zone is armed Note PIR Detectors will also detect animals so ensure that pets are not permitted access to areas...

Страница 11: ...range of the Device Installing and configuring the PIR Movement Detectors Ensure that the Control Panel is in Test mode 1 Undo and remove the fixing screw from the bottom edge of the PIR Detector Care...

Страница 12: ...ver Push the lower edge of the PIR Detector into place and refit the fixing screw in the bottom edge of the PIR Detector to secure in position Do not over tighten the fixing screws as this may damage...

Страница 13: ...If an additional wired Magnetic Contact Detector is required this should be wired to the terminal block provided in the battery compartment The wired contact should be connected using two core 24AWG...

Страница 14: ...ing provides full protection against adverse weather conditions An LED Strobe unit is built into the siren to act as a visible deterrent indication that the system is active The Strobe LEDs will slowl...

Страница 15: ...6mm holes and fit the wall plugs 3 Fit the two 30mm fixing screws in the top holes leaving approx 10mm of the screw protruding 4 Fit the top keyhole slots of the mounting plate over the screw heads A...

Страница 16: ...e rechargeable battery to the charging leads Connect the Red lead to the Red terminal and the Black lead to the Black terminals Note Once the batteries have been connected the Siren will be operationa...

Страница 17: ...device is tested in turn as it is installed refer to testing instructions for particular device Testing an Installed System The Control Panel has a programmed test routine You may test the system at a...

Страница 18: ...lled Press to exit voice dialer test Factory Defaults Reset Factory Default Conditions 1 Press to place the system in Test Mode 2 Undo the Control Panel cover fixing screws and open the cover 3 Switch...

Страница 19: ...D OFF House Code DIP Switch Off Press to save the new setting and return to programming Press to return to programming mode without saving b Using a Remote Control With the required House Code already...

Страница 20: ...imit of the external Siren expires whichever occurs first Part Arm Default setting Zone 1 Disabled Zones 2 6 Active Press The zone LEDs corresponding to the zones currently active during Part Arm mode...

Страница 21: ...ll illuminate 0 2 seconds 1 30 seconds 2 1 minute 3 3 minutes 4 5 minutes 5 equal to Alarm Duration Press the key corresponding to the required Hardwired output activation period the corresponding zon...

Страница 22: ...e in the number when dialed Press to save the new number and return to programming mode Press to return to programming mode without saving Alarm Message Play Time This is the total time for which the...

Страница 23: ...he phone number The LED will toggle between states each time the button is pressed Press to save the new number and return to programming mode Press to return to programming mode without saving Call A...

Страница 24: ...pires If the system has not been Disarmed when the Entry Delay expires a Full Alarm condition will be initiated If a Full Alarm condition occurs the appropriate zone LED that triggered the alarm will...

Страница 25: ...ll be initiated even if the system is disarmed The alarm condition will continue either for the alarm duration when the system will automatically reset or until the system is Disarmed from the Remote...

Страница 26: ...s covered with a light proof material to prevent it being energized Control Panel The rechargeable batteries have a typical life of 3 4 years and need no maintenance during this period provided they a...

Страница 27: ...o your system and to assist Trouble Shooting Zone Settings You may make a note of your User Access Code and System House Code below User Access Code System House Code Use the above diagram to record y...

Страница 28: ...the House Code is correctly set 2 Ensure Detector is within effective radio range of the Control Panel and equipment is not mounted close to metal objects 3 Detector battery low Replace Detector batte...

Страница 29: ...ted a Ensure jumper link removed b Check that additional contact is correctly wired c Ensure that Magnet is correctly positioned in relation to Detector and that the gap between Magnet and Detector is...

Страница 30: ...your statutory rights and is valid for UK and EIRE only If you believe the product to be faulty or in the unlikely event of the product developing a fault during the warranty period then please contac...

Страница 31: ...Notes 31...

Страница 32: ...peration time in complete darkness up to 25 days 95dB Piezo Siren 3 minute alarm duration limiter optional Auto reset Siren Disable selectable Dual front and rear anti tamper protection Jamming Detect...

Отзывы: