Entry / Exit Warning Tone
Default setting: ON
Press
The zone 1 LED will illuminate to indicate the current
status of the Entry/Exit warning tone.
LED ON Tone enabled
LED OFF Tone disabled
Press to change the setting to the opposite
state.
Press to save the new setting and return to
programming mode.
Press to return to programming mode without
saving.
Jamming Detection
This feature controls the Control Panels RF jamming
detection circuitry, which if enabled, will continuously
scan for radio jamming signals on the system
operating frequency.
Default setting: OFF
Press
The zone 1 LED will illuminate to indicate the current
Jamming Detector status.
LED ON Jamming Detection enabled
LED OFF Jamming Detection disabled
Press to change the setting to the opposite
state.
Press to save the new setting and return to
programming mode.
Press to return to programming mode without
saving.
Note: The jamming detection program setting will
only control the jamming detection feature in the
Control Panel.
Hard-Wired Siren
Default setting: equal to Alarm Duration
Press
The zone LED corresponding to the current setting
will illuminate.
0 2 seconds
1 30 seconds
2 1 minute
3 3 minutes
4 5 minutes
5 equal to Alarm Duration
Press the key corresponding to the required Hardwired
output activation period, the corresponding zone LED
will illuminate as the setting is changed.
Press to save the new setting and return to
programming mode.
Press to return to programming mode without
saving.
Zone Operating Modes
Each alarm zone may be programmed to operate in
one of 5 different modes depending on the type of
alarm function it is required to perform.
Panic Alarm
- used to provide 24 hour monitoring of any Panic
Switch fitted to the system. Activation of any Panic
Switch will immediately initiate a Full Alarm condition.
24 Hour Intruder
- used to provide 24 hour monitoring of areas
requiring continuous security protection even while
the system is Disarmed, (e.g. gun cabinet, safe
etc). Activation of any Detector on a security zone
will immediately initiate a Full Alarm condition.
Fire
- used to provide 24 hour monitoring of any
Fire/Smoke Detectors fitted to the system.
Activation of any Detector will immediately initiate
a Full Alarm condition.
Test
- when the system is armed, any Detector on the zone
will cause the appropriate zone LED on the Control
Panel to flash without initiating a Full Alarm condition.