SYSTEM OPERATION
SeaBat 7125 ROV Operator‟s Manual
Page 57
May 30, 2011
Version 3
5.3.3.2 Recommended Actions
In most cases, information is provided to the operator to rectify the problem. For instance
an alarm indicating missing sound velocity input to the 7125 processor will require the
operator to check the instrument and the input.
If errors occur that result in a condition where the systems in not operable the following
actions are recommended.
1. Exit any active applications.
2. Shut down the processor completely.
3. Restart the processor. (Use Shut Down from the menu rather than Restart.)
4. If the condition persists after a shutdown and restart, contact RESON
Service (
For a description of event messages and recommended actions, see
5.3.4 1PPS Input Indicator
The 1PPS input indicator reveals the selection that has been made in the Trigger/PPS
Configuration dialog (see
section 4.2.5.3 1PPS Polarity
).
Plus sign (+) = Rising edge of the 1PPS signal will be used.
Minus sign (-) = Falling edge of the 1PPS signal will be used.
Green = 1PPS signal is being received.
Yellow = 1PPS signal has been lost for at least 3 seconds.
Red = 1PPS signal has been lost for at least 15 seconds.
5.3.5 Normalization Indicator
The Normalization indicator reveals the current channel normalization status of the
system (see
section 4.3 Channel Normalization
Green = System has been normalized.
Yellow = Normalization is in progress.
Red = System has not been normalized.