TROUBLESHOOTING
SeaBat 7125 ROV Operator‟s Manual
Page 122
May 30, 2011
Version 3
Message
Description
Action
Alarm Type
Error creating PCI Reader thread
Software detected a failure to configure
the main data acquisition and
distribution module (PCI). This can be
caused by errors in the configuration
files, or corrupted installation.
Reboot the PC, call RESON support.
General System
Startup
Error starting I&Q Reader thread.
A module has failed to start correctly.
Reboot the system.
System Resource
Error starting I&Q threads
A module has failed to start correctly.
Reboot the system.
System Resource
Error starting IQ thread.
A module has failed to start correctly.
Reboot the system.
System Resource
Error starting PCI Copier thread.
A module has failed to start correctly.
Reboot the system.
System Resource
Error starting PCI Reader thread
A module has failed to start correctly.
Reboot the system.
System Resource
External triggering has failed. Check/update
software installation.
The pulse is not being detected. Time
stamping will be done using system
time only. 1 millisecond accuracy not
possible.
Check input signal cabling.
Input Signal
(Timing and
Triggers)
Failed to allocate memory for ADMXRC
read.
The software could not allocate enough
system memory to perform the
operation.
Make sure no other software is running
on the processor. Reboot the system.
General System
Startup
Failed to allocate memory for ADMXRC
transfer.
The software could not allocate enough
system memory to perform the
operation.
Make sure no other software is running
on the processor. Reboot the system.
General System
Startup
Failed to allocate memory for ADMXRC
transfer.
One or more of the processing cards
has failed to initialize or is non-
functional within the processor.
Reboot processor and try again.
PCI Card
Failed to configure 1st FPGA with <x>,
ERROR =
One or more of the processing cards
has failed to initialize or is non-
functional within the processor.
Reboot processor and try again.
PCI Card
Содержание SeaBat 7125 ROV
Страница 2: ...This page intentionally left blank...
Страница 4: ...SeaBat 7125 ROV Operator s Manual Page ii May 30 2011 Version 3 This page intentionally left blank...
Страница 14: ......
Страница 63: ...SYSTEM CONFIGURATION SeaBat 7125 ROV Operator s Manual Page 47 May 30 2011 Version 3...
Страница 199: ......