Adjustment channels
Channel
Sub channel 1
Sub channel 2 Factory setting
Change to
Description
Page
ARR
1
5
System
ROSA
0000
225
ROSA number
VLOG
1
Valve logic
LOAD1 >
Loading 1
DT1O
6.0 K [12.0 °Ra]
Switch-on temperature difference 1
DT1F
4.0 K [8.0 °Ra]
Switch-off temperature difference 1
DT1S
10.0 K [20.0 °Ra]
Set temperature difference 1
RIS1
2 K [4 °Ra]
Rise 1
S1MAX
60 °C [140 °F]
Tank maximum limitation 1
SMXS1
2
Sensor tank max 1
LOAD2 >
Loading 2
DT2O
6.0 K [12.0 °Ra]
Switch-on temperature difference 2
DT2F
4.0 K [8.0 °Ra]
Switch-off temperature difference 2
DT2S
10.0 K [20.0 °Ra]
Set temperature difference 2
RIS2
2 K [4 °Ra]
Rise 2
S2MAX
60 °C [140 °F]
Sensor tank max 2
LST2
ON
Loading tank 2
LOAD3
Loading 3
DT3O
6.0 K [12.0 °Ra]
Switch-on temperature difference 3
DT3F
4.0 K [8.0 °Ra]
Switch-off temperature difference 3
DT3S
10.0 K [20.0 °Ra]
Set temperature difference 3
RIS3
2 K [4 °Ra]
Rise 3
S3MAX
60 °C [140 °F]
Sensor tank max 3
LST3
ON
Loading tank 3
COL >
Collector
CEM
130 °C [270 °F]
Collector emergency temperature
OCCO*
OFF
Collector cooling option
CMAX
110 °C [230 °F]
Collector maximum temperature
OCMN
OFF
Collector minimum limitation option
CMIN
10.0 °C [50.0 °F]
Minimum collector temperature
OTCO
OFF
Evacuated tube collector function option
TCST
07:00
Tube collector starting time
TCEN
19:00
Tube collector ending time
TCRU
30 s
Tube collector runtime
TCIN
30 min
Tube collector standstill interval
OCFR
OFF
Collector antifreeze option
CFR O
4.0 °C [40.0 °F]
Antifreeze temperature collector on
Содержание DeltaSol BX L