6.3
Overview of options and their para meters
In the following, the additional options and para meters are listed.
The options and parameters displayed depend on the system as well as on the op-
tions and functions which have been selected. Some of the options and para meters
will only be displayed, if they are available with the individual adjustments.
Channels
Channel
Sub channel 1
Sub channel 2
Factory setting
Change to
Description
Page
COOL >
Cooling functions
OSYC*
OFF
System cooling
DTCO
20 K [40 °Ra]
Switch-on difference system cooling
DTCF
15 K [30 °Ra]
Switch-off difference system cooling
OSTC
OFF
Tank
cooling
OHDP*
OFF
Heat dump
OTCL
110 °C [230 °F]
Overtemperature collector
OTPUM
OFF
Pump or valve logic
ODTFT >
Δ
T function option
DT4O
6.0 K [12.0 °Ra]
Δ
T function switch-on difference
DT4F
4.0 K [8.0 °Ra]
Δ
T function switch-off difference
RIS4
2 K [4 °Ra]
Δ
T function rise
TH1O
65.0 °C [150.0 °F]
Thermostat function 1 switch-on temperature
TH1F
60.0 °C [140.0 °F]
Thermostat function 1 switch-off temperature
TH2O
45.0 °C [120.0 °F]
Thermostat function 2 switch-on temperature
TH2F
50.0 °C [125.0 °F]
Thermostat function 2 switch-off temperature
DTREL
4
Δ
T function relay
OTH >
Thermostat function option
THNHE
40 °C [110 °F]
Thermostatic backup heating switch-on temperature
THNHA
45 °C [120 °F]
Thermostatic backup heating switch-off temperature
S TH
3 / 5
Thermostatic backup heating sensor
RTH
Thermostatic backup heating relay
t1O
06:00
Thermostatic backup heating switch-on time 1
t1F
22:00
Thermostatic backup heating switch-off time 1
t2O
00:00
Thermostatic backup heating switch-on time 2
t2F
00:00
Thermostatic backup heating switch-off time 2
t3O
00:00
Thermostatic backup heating switch-on time 3
t3F
00:00
Thermostatic backup heating switch-off time 3
PUMP >
Speed
PUMP1
PSOL
Speed variant pump 1
n1LO
20 %
Minimum speed
n1HI
100 %
Maximum speed