4
Erbas Teknoloji - Reporter LX1148-DGR/B/H User Manual
send SMS to device in standby mode, you will not be able to reach the device. It attaches to the network
again once external power is restored.
All settings and registered admin & user numbers are saved in Reporter
’s own memory. So, settings will
not be deleted if battery or SIM card is removed. Device will continue with new batteries or new SIM Card
with the last saved settings & numbers.
2.
USECASES
2.1.
Remote Controlling
This device can be used to control electrically operated devices remotely via SMS Commands or Phone
Calls. With the help of high capacity & operation configurable relays, you may Activate, Deactivate,
Trigger or Time-Based Activate your remote devices. All Admins and Users can use these control
functions.
Use cases might be such as:
-
Irrigation systems
-
Trigger Gate openers / barriers
-
Control Lighting
-
Control total electricity of your home/office/plant etc.
-
Different kinds of motors and machines and much more
…
As soon as integrated relay power is suitable (up to 10A / 240VAC), any kind of
device/machine/system could be controlled with this device. In some cases where required switching
power is higher than the device capacity; then it can still control those devices by some additional
high capacity switching equipment (i.e. contactors).
2.2.
Input Monitoring
Any kind of volt-
free or +3V…+27VDC voltage
ranged sensor/switch/device output could be
connected to Reporter isolated inputs. Thus, Reporter will continuously check for any change on the
inputs, and it will inform all Admins by SMS (optionally Free Phone Call) in case of changes on the
inputs.
Use cases might be such as:
-
Burglar alarm systems as a dialer
-
Fire alarm systems as a dialer
-
Door/window monitoring
-
Any sensors like gas/smoke/earthquake monitoring
-
Water level monitoring
-
Flood monitoring
-
Panic alarm monitoring
-
Specific electronic devices/system monitoring
and much more…
2.3.
Power Failure / Restoration Monitoring
If batteries used; Reporter will inform you in case of power failures and restorations.