Erbas Teknoloji - Reporter LX1148-DGR/B/H User Manual
4.2.
Connect Inputs and Outputs on Ports
Note: Wires should pass into the holes of the bottom cover! Please check Wiring Diagram!
If you want to apply external powered lines to the inputs; make sure voltage levels are b3V
and +27V.
It is also very important that you need to connect external device’s GND line to Reporter
GND terminal.
If your external equipment is volt-free (i.e. a button, switch, magnetic contact or volt-free relay
o
utput); in this case you may use Reporter’s +12V line to supply your external equipment.
Reporter inputs are digital and isolated.
4.3.
Insert Batteries (Optional)
Insert two pieces of CR123A or CR123 lithium batteries in case of power failure feature is required.
Make sure you followed correct polarity of the batteries. You will see + / - indications on the board.
4.4.
Connect Power
Note: Wires should pass into the holes of the bottom cover! Please check Wiring Diagram!
Connect 12V DC power supply into terminal block +12V (positive) and GND (negative/ground).
Two pieces of +12V and two pieces of GND pins are internally
parallel.
Please note external power should be rated at +12VDV and
current should be at least 1000 mA (1A).
5.
DEVICE CONFIGURATION
Firstly, make sure “POWER LED” (Red one) is ON. This indicates that external power is ON.
Then check for “NETWORK STATUS LED”.
-
Off
: Powered off
-
Fast Blink
: Not ready (registering to network)
-
Slow Blink
: Ready (registered to the network)
Once NETWORK STATUS LED starts blinking slowly; then you are ready to go to next steps.
Note: Device Configuration and Reset is only made by SMS commands. There is no other method.