following section describes
the available configuration
parameters in more detail.
Radio settings
The radio settings control parameters related to the radio
interface.
Mode
A Trinity unit can operate in three different modes as described
in the table below.
Point-to-Point Master
Defines the channel to operate on and the
distance to its client. Which client that is
allowed to connect is determined by the
remote MAC address setting.
Multi-Point Master
Same as Point-to-Point Master, except it will
allow multiple clients to connect at the same
time, on a timeslot division basis. In Multi-
Point Master mode, use the 'Client settings'
menu to configure timeslot allocation etc for
the clients.
Client
The client will attempt to connect to any
master that matches its configured remote
MAC address.
Remote MAC
Radio device MAC address of the remote peer.
Channel
Specifies which radio channel that should be used. Selecting “Auto
channel” will make the unit sweep the spectrum and select a
channel free from other transmissions. Only required on the
Master side.
Note
For European ETSI domains the frequency range 5.15-
5.35 GHz is solely for indoor use. It is not allowed to use channels
within this band in an outdoor installation.
Min Transmit rate
This setting configures the lowest allowed modulation to be
used. Will be clamped to Max Transmit rate if set to higher rate
than Max Transmit Rate. Note that when in Multi-Point Master
mode, this setting only applies to broadcast/management traffic,
the Min Transmit rate to the clients is set individually in the