REOVIB MFS 268 UL/CSA
Operating Instructions
6
ELEKTRONIK
4.0 Technical Data
Model Type
MFS 268 / 3A
MFS 268 / 6A
MFS 268 / 8A
MFS 268 / 12A MFS 268 / 16A
Supply voltage
110 V, 240 V +/- 10 %, 50/60
Output
0...95 V, 0...205 V
Output current
Max. 3 A
Max. 6 A
Max. 8 A
Max. 12A
Max 16 A
Recommended *
Protection
10 A Anti-surge 16 A Anti-surge 16 A Anti-surge 16 A Anti-surge 16 A Anti-surge
Type D current trip device
Enable
24 V, DC input (connect to internal 24 V reference)
Status relay
Change-over contacts, 250V, 1 A
Sensor supply
24 V, DC, 100 mA
Sensor type
PNP output
Status output
Relay, change-over contact 1A, 250 VAC , 60 VDC
Switch-on frequency
of the power supply
wait 5 seconds until resetting the power supply
Solenoid valve out-
put
24 VDC / 50 mA switched with feeder unit (PNP), short-circuit
protected
not provided at
IP 20 versions
Operating tempera-
ture
0...+45 °C
Storage temperature -10...+80 °C
Altitude
1000 m 0,5 % rated current reduction for each additional 100 m
* The units are provided with switch-on, current damping. However it is still possible that some
internal capacitor, energising, current spikes will be generated, especially when several units are
switched on simultaneously. Therefore, fuses and overload trips should have anti current surge
characteristics.
5.0 Ordering Codes (UL / CSA units)
Type
Order Code Construction
REOVIB MFS 268-3A–IP 20
621607
3 A, Panel mounting with track control and accelerometer
regulation
REOVIB MFS 268-6A–IP 20
621614
6 A, Panel mounting with track control and accelerometer
regulation
REOVIB MFS 268-8A–IP 20
621621
8 A, Panel mounting with track control and accelerometer
regulation
REOVIB MFS 268-16A–IP 20
621110
16 A, Panel mounting with track control and accelerometer
regulation
REOVIB MFS 268-6A–IP 54
626825
6 A, Enclosed construction with track control and accelerometer
regulation
REOVIB MFS 268-8A–IP 54
626845
8 A, Enclosed construction with track control and accelerometer
regulation
REOVIB MFS 268-12A–IP 54
626865
12 A, Enclosed construction with track control and accelerometer
regulation
REOVIB MFS 268-16A–IP 54
626885
16 A, Enclosed construction with track control and accelerometer
regulation
For use in NFPA 79 Applications only
E217179
Adapters providing field wiring means are available from REO ELEKTRONIK AG.
Refer to REO ELEKTRONIK AG.
6.0 Declaration of Conformity
We declare that these products conform with the following standards: EN 61000-6-4 and
EN 61000-6-2 in accordance with the regulations of guidelines 2004/108/EC.
REO ELEKTRONIK AG, D-42657 Solingen
RoHS
COMPLAINT