REOVIB MFS 268 UL/CSA
Operating Instructions
5
ELEKTRONIK
2.3.4 Output status relay
Status-Relay contact 250 V/1 A (changeover). Relay closes when the feeder is running – the relay opens
when there is no enable signal or a fault displayed.
2.3.5 Time-Out output 24 VDC
"time Out" message active, if after adjusted time no material is recognized by the sensor (adjustable with
parameter "E."). (not on IP 20 units)
2.3.6 Air valve output 24 VDC
Output for air blast, comes on with feeder and switches off, 4 sec., after feeder stops (not on IP 20 units)
2.4 Display
Initialisation phase, when supply voltage is connected (left decimal point blinks).
Normal Mode: The throughput set point is displayed
Output switched off using the `0` button
Unit inhibited by the enable input
Output switched off by the track control sensor
Under voltage, input voltage is to low.
3.0 Construction
The units are available as stand-alone, enclosed or panel mounting versions .
3.1 Enclosed units
•
Mains switch
•
Touch panel with display
•
Mains cable with plug
•
Output cable or output socket for connecting to the feed system
•
Sensor socket. The standard unit has provision for 24 VDC sensors with a PNP output
3.2 Panel mounting units
•
Touch panel with display
•
Terminals for electrical connections
•
Screw hole fixings for mounting