10.0 Setting Instructions
10.1 User adjustment of throughput
Code C. 000
A further set point code can be found under C002
(for use in coarse/fine operation)
10.2 Tuning the feed system
10.2.1 Feeder settings
Code C. 020, 096
P
P
P
P
P
P
P
P
P
P
P
P
Soft start 0...60 Sek.
Soft stop 0...60 Sek.
Running mode
Vibration frequency [Hz]
Max. output 100...5 %
Feeder amplitude set point
0...100 %
P
F
Setting the maximum limit
1. Adjust set point to zero
2. Set parameter P (maximum limit) to 50.
3. Adjust set point to 100%
4. Increase the limit P from 50% until the required amplitude is reached
5. The full set point range of 0…100% can now be used
Feeder amplitude set point
0...100 %
Running mode
P
P
P
P
P
P
P
P
P
P
Feeder amplitude set point
0...100 %
2
nd
Feeder amplitude set point
0...100%
(only if "SP.2. = I)
Running mode