![Renova turborex TSP 180 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/renova/turborex-tsp-180/turborex-tsp-180_operating-instructions-manual_1442997018.webp)
18
replacement of RPM counter
•
Remove the power supply to the fans because the moving blades can be
dangerous for the operator’s fingers.
•
Remove the pneumatic power supply.
•
Disconnect the sensor from the connector.
•
Remove the sensor by unscrewing the nut that locks it on the bracket.
•
Remove it from the eyelets and from the thermal protection sheath.
•
Mount the new sensor on the bracket and adjust the distance from the
central disc to about 1mm.
•
Insert the cable into the eyelets and into the thermal protection sheath.
•
Connect the 3 poles to the connector contacts according to the previously shown diagram (ref page 13).
•
Power up the tachometer and check for proper operation by turning the central cam disc and observing
the light on the sensor head turning on.
kit temperature sensor - lamp (KT000000000)
Another optional that Renova provides concerns the kit including the temperature sensor and signaling lamp.
Thanks to these options it is possible to monitor that the brake temperature does not rise above the threshold
and if this happens it will be signaled by a light signal emitted by the lamp.
Signalation lamp Temperature sensor